background image

CONTINUITY CHECK

 

WARNING: 

To avoid electric shock, never measure continuity on 

circuits or wires that have voltage on them. 

1.  Set the function switch to the      position. 

2. 

Insert the black lead banana plug into the negative (-) jack (COM) 

and the red test lead banana plug into the positive (+) jack (

˖

). 

3. 

Touch the test probe tips to the circuit or wire you wish to check.   

4.  If the resistance is less than approximately 50

˖

, the audible 

signal will sound. The display will also show the actual resistance. 

DIODE TEST 

WARNING: 

To avoid electric shock, do not test any diode that 

has voltage on it. 

1.  Set the function switch to     position. 

3.   Insert the black test lead banana plug into the negative (-) jack 

(COM) and the red test lead banana plug into the positive (+) 

jack (

˖

). 

4.

 

  Touch the test probe tips to the diode or semiconductor junction 

you wish to test. Note the meter reading 

5.  Reverse the probe polarity by switching probe position. Note this 

reading. 

6.   The diode or junction can be evaluated as follows: 

A. If one reading shows a value and the other reading shows “1”, 

the diode is good. 

B. If both readings show “1”, the device is open. 

C. If both readings are very small or 0, the device is shorted. 

 

NOTE:

    The value indicated in the display during the diode check is 

the forward voltage. 

FREQUENCY MEASUREMENT

 

1.   Set the function switch to the 20KHz position. 

2.   Insert the black test lead banana plug into the negative (-) jack 

(COM) and the red test lead banana plug into the positive (+) 

jack (F). 

3.   Touch the test probe tips to the circuit under test. 

4.  Read the frequency in the display. The digital reading will 

indicate the proper decimal point, value. 

CAPACITANCE MEASUREMENTS 

WARNING:

 To avoid electric shock, disconnect power to the unit 

under test and discharge all capacitors before taking any 

capacitance measurements. Remove the batteries and unplug 

the line cords. 

1. Set the function switch to the CAP position.   

2. Insert the black test lead banana plug into the negative (-) jack 

(COM) and the red test lead banana plug into the positive (+) jack 

(CAP). 

3. 

Touch the test leads to the capacitor to be tested. The 
display will indicate the proper decimal point, value

 

TEMPERATURE MEASUREMENTS 

WARNING: 

To avoid electric shock, disconnect both test probes 

from any source of voltage before making a temperature 

measurement. 

1. If you wish to measure temperature in 

o

F, set the function switch to 

the 

o

F range. If you wish to measure temperature in 

o

C, set the 

function switch to the 

o

C range. 

2. Insert the Temperature Probe into the negative (-) jack (COM) and 

the positive (+) jack (Temperature), making sure to observe the 

 13 

                                                                                                           

 14 

 

Содержание AMM-1008

Страница 1: ......

Страница 2: ...not avoided could result in death or serious injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the product This symbol advises the user...

Страница 3: ...oF at 70 relative humidity Storage temperature 20 oC to 60 oC 4 oF to 140 oF at 80 relative humidity For inside use max height 2000m Pollution degree 2 Power One 9V battery NEDA 1604 IEC 6F22 Dimensi...

Страница 4: ...ts 200 0nF 0 1nF 2 000uF 1nF 4 0 of rdg 3 dgts 200 0uF 0 1uF 4 0 of rdg 5 dgts Input Protection 250V dc or 250V ac rms Frequency Range Resolution Accuracy 20 00kHz 0 01Hz 1 5 of rdg 5 dgts Sensitivity...

Страница 5: ...the function switch to the V DC position mV will appear in the display 2 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack 3...

Страница 6: ...t the black test lead banana plug into the negative COM jack 2 For current measurements up to 200mA AC set the function switch to the mA range and insert the red test lead banana plug into the mA jack...

Страница 7: ...ndicated in the display during the diode check is the forward voltage FREQUENCY MEASUREMENT 1 Set the function switch to the 20KHz position 2 Insert the black test lead banana plug into the negative j...

Страница 8: ...voltage before removing the battery door 1 Disconnect the test leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the battery into battery...

Отзывы: