www.tmatlantic.com
- 28 -
4.000k
Ω
0.001k
Ω
0.2%+4
40.00k
Ω
0.01k
Ω
0.2%+4
400.0k
Ω
0.1k
Ω
0.2%+4
4.000M
Ω
0.001
M
Ω
0.5%+4
40.00 M
Ω
0.01
M
Ω
1%+4
Capacitance Measurement
Range
Frequency
Accuracy
Remark
50.00nF 0.01nF 4%+5
500.0nF 0.1nF 2%+5
5.000µF 0.001µF 2%+5
50.00µF 0.01µF 2%+5
100µF 1µF 4%+5
To improve the accuracy of the low capacitance
value, open the circuit, and then press
to
automatically subtract the capacitance of the meter
and the leads.
Frequency Count Accuracy
Function Range
Resolution
Accuracy
Remark
50.00Hz 0.01Hz 0.1%+3
500.0Hz 0.1Hz 0.1%+3
5.000KHz 1Hz 0.1%+3
50.00KHz 0.01KHz 0.1%+3
Frequency
100.0 KHz
0.1KHz
0.1%+3
Duty cycle ratio 0.1%
~
99% 0.1%
1%
Display updates 3 times/second (at
>10Hz)
TC Measurement
Function Input
Range Resolution
Accuracy
Remark
K -200
to
950 1
0.5%+2(
≤
-100 )
0.5%+1(> -100 )
By using ITS-90 temperature scale
Note: The accuracy does not include the
error of internal temperature
compensation caused by a sensor.
The range of the internal temperature
compensation sensor is + 2 .
RTD Measurement
Function
Input Range
Resolution Accuracy
Remark
Pt100 -200
to
700 1
0.5%+2
By using Pt100-385 temperature scale
Measuring current 1mA
Note: attached lead resistance is excluded
Diode Test
Range
Frequency
Accuracy
Short Circuit current
Open Circuit voltage
1.000V 0.001V
10%
Less than 0.2mA
(
typical value
)
1.1V to1.6V
Continuity Check
Range
Frequency
Accuracy
Short Circuit current
Open Circuit voltage
400.0
Ω
0.1
Ω
Beeps if the value is less than 50
Ω
130
μ
A
(
typical value
)
<
0.45V