You always are careful when working with 
voltages above 60V dc or 30V ac rms. Keep 
fingers behind the probe barriers while 
measuring. 

To avoid damages to the instrument, do not 

exceed the maximum limits of the input values 
shown in the technical specification tables. 
Never use the meter to measure voltages that 
might exceed the maximum allowable input value 
of any function. 

 

MAINTENANCE 

1. Never touch exposed wiring, connections or  
any live circuit when attempting to take 
measurements. 
2. Before opening the case, always disconnect 
test leads from all energized circuits.   
3. Never use the meter unless the back cover is 
in place and fastened completely. 
4. Do not use abrasives or solvents on the meter. 
To clean it using a damp cloth and mild detergent 
only. 
5. Qualified and trained service technicians 
should only perform calibration and repair of the 
meter. 

Содержание ACM-2031

Страница 1: ...ACM 2031 AC DC CLAMP METER USER S MANUAL www tmatlantic com...

Страница 2: ...ETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS MAINTENANCE GENERAL DESCRIPTION PANEL DESCRIPTION OPERATING INSTRUCTIONS SPECIFICATIONS AUTO POWER OFF REPLACING THE BATTERY ACCESSORIES 1 1 2 3 4...

Страница 3: ...Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromag netic fields in the vicinity o...

Страница 4: ...will inform you of potentially dangerous proce dures The instructions in these warnings must be followed Always inspect your meter and test leads for any sign of damage or abnormality before every use...

Страница 5: ...he maximum allowable input value of any function MAINTENANCE 1 Never touch exposed wiring connections or any live circuit when attempting to take measurements 2 Before opening the case always disconne...

Страница 6: ...nuity Test with battery operated PANEL DESCRIPTION 1 Transformer jaws Pick up DC or AC current flowing through the conductor 2 Rotary switch Rotary switch is used to select functions 3 HOLD button Whe...

Страница 7: ...5 LCD display...

Страница 8: ...ement mode ZERO annunciate display on LCD But store the displayed reading as a reference value In the Relative mode the value shown on the LCD is always the difference between the stored reference val...

Страница 9: ...ul not to touch any electrical conductors The polarity of the red lead connection will be indicated along with the voltage value 3 Read the measure result from the display AC VOLTAGE MEASUREMENT 1 Ins...

Страница 10: ...y closed around the conductor 5 Read current value on LCD display NOTE As the jaw core may remain some magnetic force after using for awhile If the display can not reach 0 open the jaws several times...

Страница 11: ...display NOTE When checking in circuit resistance be sure the circuit under test has all power removed and that all capacitors have been discharged fully CONTINUITY TESTING 1 Insert the black and red t...

Страница 12: ...ively 2 Set rotary switch at desired range position Push FUNC button to select 3 Connect test leads across the capacitor under measurement and be sure that the polarity of connection is observed Note...

Страница 13: ...ange MEASURING FREQUENCY FOR CLAMP 1 Set the rotary switch to position 2 Press the trigger to open transformer jaw and to clamp one conductor only making sure that the jaw is firmly closed around the...

Страница 14: ...sition Push Hz Duty button to select mode and connect the test lead tips in parallel with the circuit to be measured Be careful not to touch any electrical conductors 3 Read the measure result directl...

Страница 15: ...pears on LCD Jaw capability 40mm Max conductor size Power Battery1 5Vu3 Size AAA Size 225mm 86mm 32mm Weight Approx 330g Operating 5 to 35 Storage temperature 10 to 50 DC VOLTAGE Range Resolution Accu...

Страница 16: ...or 700V AC RMS DC CURRENT Range Resolution Accuracy 400A 0 1A 1000A 1A r 3 0 5 Overload Protection 120 ranges for 60 seconds max AC CURRENT Range Resolution Accuracy 400A 0 1A 1000A 1A r 3 0 8 Overloa...

Страница 17: ...NT Range Resolution Accuracy 4nF 1pF 40nF 10pF 400nF 0 1nF 4uF 1nF r 4 0 10 40uF 10nF Not Specified Overload Protection 250V dc or rms ac for all ranges FREQUENCY MEASUREMENT Range Resolution Accuracy...

Страница 18: ...r 1 0 5 0 400 1 r 1 0 3 40 0 1 r 1 0 6 AUDIBLE CONTINUITY AND DIODE Range Description If continuity exists about less than 30 built in buzzer will sound Show the approx Forward voltage of the diode Du...

Страница 19: ...e electrical tester displays the mark or the backlight be not very lit the battery must be replaced to maintain proper operation Use the following procedure to replacing the battery 1 The Rotary Switc...

Страница 20: ...onment with a strong radiated radio frequency electromagnetic field approximately 3V m may influence its measuring accuracy ACCESSORIES x Operator s instruction manual x test leads x Gift box x Batter...

Отзывы: