ADJUSTMENT PROCEDURE
1. Be sure the Slo-Cloz is properly installed on the Valve.
2. Loosen the Set Screw (#8).
3. To decrease the retarding force, turn the Adjustment Plug counterclockwise.
4. Once the desired setting is achieved, retighten the Set Screw.
Note: Do not use a wrench on the Hex Plug (#9) while adjusting the Adjustment Plug.
MAINTENANCE
Under normal conditions, the Slo-Cloz device does not require maintenance. If maintenance is required, contact Akron Brass
Customer Service.
X
8
6
INDENTS
X
INDENT ON
ADJUSTMENT PLUG
7
9
Page 3