Default BiSS C Interface Setting of ITF-21-BISS-MIT
MA Clock Frequency:
1MHz (1 µs) [Encoder cable length ≤20m]
Max allowable acknowledge
duration of BiSS C encoder
35 µs
Max allowable timeout
duration
23.5µs + (35 µs
–
actual ack duration used)
Note: timeout of encoder is usually configurable. Please check
encoder datasheet.
Number of bits of position
data
12 to 32 bits
The setting above in general can support most of the situation if the encoder cable requirement is
≤
20m.
For special situations which violates the requirement above, please enquire Akribis System sales.
Basically, the adapter can support any situation if the requirement of Max Allowable of BiSS C Cycle of Adapter of 102
μs
is adhered.
Mitsubishi Serial Interface
Mitsubishi Alarm Information (ALMC)
When alarm 2A.N is triggered (where N = Alarm No. shown below) at MR-J4 driver, it means MR-J4 driver received at
least one error from ITF-21-BISS-MIT. Refer to the corresponding alarm no. shown below for the root cause.
Alarm No.
Alarm Information
1
Error from BiSS C Encoder
2
Adapter receiving CRC Error
CRC computed from data received are not equal to CRC received by BiSS
Master Interface of adapter
3
BiSS Communication Error
4
Mitsubishi protocol communication error
5
Input voltage detected by adapter is less than 4.3V
6
Configuration setting initialisation error
7
Reserved
8
Warning from BiSS C Encoder
For some reason, if user want to mask Mitsubishi Alarm No. 8 which is warning from BiSS C Encoder, user can
configure the Mitsubishi Alarm Mask thru configuration page of