31
Akribis Systems GmbH
Am Weichselgarten 19a
T: +49 (0) 9131 811 79-0
E:
D-91058 Erlangen
F:
+49 (0) 9131 811 79-99
W:
Chapter 9 - Appendix1
– Datasheet and Drawing
9.1 AVM Motor
AVM Standard Series
Model
Units
AVM12-6.4
AVM19-5
AVM 20-10
AVM24-5
AVM24-10
Stroke
mm
6.4
5
10
5
10
Force sensitivity (at mid stroke)
N/A
0.57
1.75
2.00
3.00
3.90
Back EMF constant
V/(m/s)
0.57
1.75
2.00
3.00
3.90
Continuous force (at 100 °C)
①
N
0.91
1.75
1.56
2.10
2.65
Peak force
N
3.53
7.88
7.60
11.40
14.82
Resistance
②
ohms
1.13
2.23
3.59
3.09
5.86
Inductance
②
mH
0.09
0.27
0.50
0.51
1.23
Voltage at peak force
V
7.01
10.04
13.64
11.7
22.3
Continuous current (coil at 100 °C)
A
1.60
1.00
0.78
0.70
0.68
Peak current
A
6.20
4.50
3.80
3.80
3.80
Max voltage
Vdc
60
60
60
60
60
Actuator constant
N/Sqrt(W)
0.54
1.17
1.06
1.71
1.61
Continuous power
W
2.89
2.23
2.18
1.51
2.71
Electrical time constant
ms
0.08
0.12
0.14
0.17
0.21
Mechanical time constant
ms
17.39
6.55
9.87
4.12
6.36
Clearance of coil
mm
0.35
0.40
0.50
0.50
0.50
Power at peak force
W
43.44
45.16
51.84
44.62
84.62
Thermal dissipation constant
W/°C
0.039
0.030
0.029
0.020
0.036
Max coil temperature
°C
100
100
100
100
100
Coil assembly mass
g
5.0
9.0
11.0
12.0
16.5
Core assembly mass
g
7.3
23.8
45.1
29.7
45.0
①
Continuous force measured without any additional mounting plate or heat sink on coil
②
Measured at 25 °C
Содержание 16