2.2 ELECTRICAL CONNECTION

 

 

Before connecting the hood to electricity, make sure that the voltage and frequency of 
the power supply correspond to the data indicated on the instrument panel. The hood 
must be connected to an easily accessible outlet. Removing the plug and connecting the 
hood directly to electricity is unacceptable. The hood should be connected to electricity 
after installation as indicated.

 

 

3. INSTALLATION

 

 

For a gas stove, the distance “A” between the lowest part of the hood and the cooking 
surface must be at least 65 cm (Fig. 16).

 

During assembly work, the applicable provisions regarding air exhaust must be 
observed.

 

ATTENTION:

 

If the manual of the gas or electric cooker orders a different, larger distance from 
the hood than 65 cm, then it should be used.

 

 

 

 

 

 

 

 

 

 

 

Fig.

 16

 

3.1 INSTALLATION OF EXHAUST HOUSING LIGHT, P3050/60

 

 

 

Disassemble the aluminum grease filter (Fig. 17),

 

 

Prepare the cabinet with the appropriate dimensions depending on the type of eaves

 

LIGHT GLASS / LIGHT / LIGHT ECO / LIGHT ECO R/ LIGHT ECO GLASS / 

LIGHT PLUS (Fig. 18), P3050 (Fig. 22), P3060 (Fig. 23),

 

 

Put the hood into the previously prepared cabinet (Fig. 19),

 

Содержание WK-7

Страница 1: ...N HOOD WK 7 ENG Manufacturer Production and trading enterprise AKPO Spółka jawna 05 080 Izabelin Laski ul Łąkowa 10 www akpo pl Production plant 06 430 Sońsk ul Ciechanowska 26 phone 0 23 671 34 70 fax 0 23 671 34 72 ...

Страница 2: ...e the room or in the absorption mode internal circulation It is designed to be installed above a gas or electric stove It has its own lighting and exhaust turbine with a choice of one of three speeds of operation Note Save the purchase receipt along with a stamped warranty card for a potential complaint Without these documents the warranty is void The manufacturer shall not liable for damages or d...

Страница 3: ...talled as a vent a check valve should be installed Fig 2 with two folding valves that prevent the return of air from the ventilation pipe On the check valve there is an installed pipe for air exhaust a OUTLET b ABSORBER P3050 60 K50 60 Light Fig 4 ATTENTION The air from the eaves should not be discharged to the chimney used to evacuate gases from gas burning appliances or other fuels The hood has ...

Страница 4: ...l a collar Ø 120 mm with a non return valve Fig 5 Fig 5 2 Outlet at the back in the rear opening of the hood there are two wings which should be cut from the bottom Fig 6 In order to facilitate removing of the air curtain cut the curtain with a knife across the center Fig 7 and remove it through the upper hole Fig 8 Then put the end cap on the upper hole Fig 9 ...

Страница 5: ...5 Fig 6 Fig 7 Fig 8 ...

Страница 6: ...issors along the groove Fig 11 and Fig 12 The cut curtain must be placed into the hood turbine and screwed on again Fig 13 and Fig 14 Put the end plug on the upper outlet Fig 15 the cleaned air is ejected through the front outlet openings of the hood ATTENTION If the hood is supposed to work as an absorber do not remove the air curtain used as the rear air outlet ...

Страница 7: ...7 Fig 10 Fig 11 ...

Страница 8: ...8 Fig 12 Fig 13 ...

Страница 9: ...9 Fig 14 Fig 15 ...

Страница 10: ...tween the lowest part of the hood and the cooking surface must be at least 65 cm Fig 16 During assembly work the applicable provisions regarding air exhaust must be observed ATTENTION If the manual of the gas or electric cooker orders a different larger distance from the hood than 65 cm then it should be used Fig 16 3 1 INSTALLATION OF EXHAUST HOUSING LIGHT P3050 60 Disassemble the aluminum grease...

Страница 11: ...rill two holes in the wall to attach the cover to the wall using the included 10x50 dowels If the cap will be used as an exhaust cap Fig 4a install a non return valve Fig 5 into the outlet of the turbine and install a steam return pipe Fig 21 on it Install the aluminum grease filter Fig 17 Fig 17 Fig 18 ...

Страница 12: ...12 Fig 19 ...

Страница 13: ...13 Fig 20 Fig 21 P3050 ...

Страница 14: ...14 Fig 22 P3060 Fig 23 ...

Страница 15: ...ontrol without display A B C D E F Fig 24 A B Fig 25 A B C D E Fig 26 Control Fig 24 A turning the light on and off B turbine speed I C turbine speed II D turbine speed III E turbine shut down F turbine lamp Control Fig 25 A turning the light on and off B turbine speed I II and III Control Fig 26 ...

Страница 16: ...wn of the turbine and lighting after 15 minutes TIMER To enable this feature Press the turbine operation select button until the indicator light flashes above the button The timer is on Remote The hood LIGHT PLUS can be controlled using the remote control Fig 27 Button definition fig 27 1 TIMER Triggers a temporary hood switch 2 MINUS Adjusts the speed of the turbine to turn off 3 PLUS Turns the t...

Страница 17: ...ed in a vertical position When cleaning the aluminium filter take care not to damage the mesh After washing and drying insert the filter in its place in the hood When the aluminium filter works in the drain mode and is not cleaned regularly it wears out faster and the efficiency of the hood diminishes Fig 28 5 2 CARBON FILTER In operating mode as an absorber carbon filters absorb odors associated ...

Страница 18: ...all a new filter on the turbine engine housing and turn it well to protect it against slipping Fig 29 Fig 30 5 3 LIGHTING LIGHT hoods can be equipped with LED lighting with GU10 fixing or filament lamps depending on the model see product card Fig 31 Fig 32 Replacing light bulbs Fig 31 1 To replace an ordinary light bulb 2 Open the grease filter screens 3 On the inside of the hood unscrew the light...

Страница 19: ...instructions there is a risk of fire 2 If you use a gas stove do not leave open fire 3 The device is not intended for use by persons including children with physical sensory or mental disabilities 4 The device is not intended to entertain children 5 The air from the hood must not be vented to the chimney used to remove exhaust gases from gas combustion devices or other fuels 6 If the permanently b...