AKO AKO-D1460 Series Скачать руководство пользователя страница 2

Table of parameters and messages

Def.

 column shows factory-set default parameters. Those marked with 

*

 are variable parameters depending on the application chosen in the wizard (see Start-up ). Unless otherwise stated, temperatures are expressed in °C.

OK

Change set point

SET

SET

5"

SET

Temperature 

Indication

Temperature 

Indication

Current 

Value

New 

Value

OK

Programming Menu (parameters)

After 20 seconds with no key being pressed, the equipment will return to the previous level. If you are on level 3, the changes will not be saved.

OK

20"

PROGRAMMING

SET

SET

SET

OK

10"

20"

20"

Back up one level
without saving changes

SET

SET

SET

Temperature 

Indication

Level 1

Menu

Level 2 

Parameters

Level 3

Values

Change

Menu

Change

parameters

Change

value

Change

value

SET

SET

Release 

SET

to access

programming

t

Temperature

Indication

Release 

SET

to access the

set point

5 sec.

10 sec.

Technical specifications

Power supply

Maximum Voltage SELV circuits
Inputs

input 

input 

digitised inputs

According to P4

inputs 

digitised inputs

inputs 

digitised input

Number of relay operations

operations

Types of probe
Measurement range

Resolution

Connections

Connections via screw terminals for cables up to 2.5 mm²

Rating  of  control  device

automatic  operation  feature Type  1.B,  for  use  in  clean 

environments, Class A software and continuous operation. Pollution classification 2 s / UNE-EN 60730-1.
Double insulation between supply, secondary circuit and relay output.
Rated pulse voltage
Temperature during ball-pressure test

Accessible parts
Parts which position active elements

Voltage and current as per EMC test

Current of radio jamming supression tests

AKO-D14602 / AKO-D14610

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V~ ±10 % 50/60 Hz 3.5 VA

AKO-D14622 / AKO-D14632 / AKO-D14642

. . . . . . . . . . . . . . . . . 230 V~ ±10 % 50/60 Hz 3.75 VA

AKO-D14601 / AKO-D14612 / AKO-D14621 / 
AKO-D14631 / AKO-D14641

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 V~ +8 % - 12 % 50/60 Hz 4 VA

AKO-D14622-C / AKO-D14632-C / AKO-D14642-C

. . . . . . . . . . . . . . . . . 90-240 V~ 50/60 Hz 7 VA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V

AKO-D1460x / AKO-D1461x

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 

NTC/PTC

AKO-D1462x

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 

 NTC/PTC + 2 

AKO-D1463x / AKO-D1464x

 (

) . . . . . . . . . . . . . . . . . 2 

NTC + 2 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 

NTC + 1 

Relay COOL 16 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  (EN60730-1: 12(10) A 250 V~)
Relay DEF 8 A  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 8(4) A 250 V~)
Relay FAN 16 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 12(10) A 250 V~)
Relay AUX 6 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 5(4) A 250 V~)
Relay ALARM 6 A (AKO-D1462x). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 5(4) A 250 V~)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN60730-1: 100.000 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NTC 

AKO-149xx

 / PTC 

AKO-1558xx

NTC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +99,9 ºC (-58,0 ºF to 210 ºF)
PTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +150 ºC (-58,0 ºF to 302 ºF)

-50 to 100 ºC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1 ºC
> 100 ºC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ºC

Working environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10 to 50 ºC, humidity <90 %
Ambient storage humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30 to 70 ºC, humidity <90 %
Class of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP40
Fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wall assembly, adaptable to built-in housing
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 x 94 x42 mm

. . . . . . . . . . . . . . . . . . . . . . . . . . .

:  Independent  mounting, 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 ºC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 ºC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AKO-D14602 / D14610 / D14632 / D14622 / D14622-C / D14632 /
D14642 / D14632-C / D14642-C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 V, 17 mA

AKO-D14601 / AKO-D14612 / AKO-D14621 / D14631 / D14341

. . . . . . . . . . . . . . . . 105 V, 36 mA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 mA

MESSAGES

L5

Access code (Password) request 

D

-

dEF

Indicates a defrost is underway. (Only if parameter d2=2)

D

-

E1/E2/E3

Probe 1 / 2 / 3 faulty (

open circuit, crossover or temperature outside the probe limits

D A

InI

Setup wizard (See section “Start-up”)

D

-

AH

Flashing: 

maximum temperature alarm on probe 1 (A1)

D A

AL

Flashing: 

minimum temperature alarm on probe 1 (A2)

D A

AE

External alarm activated (only if parameter P10 or P11=2)

D A

AES

Severe external alarm activated (only if parameter P10 or P11=3)

D A

Adt

Defrost time-out alarm (only if parameter A8=1)

D

-

PAb

Door open alarm (Only if P10 or P11=1 and as per time at A12)

D

-

Pd

Flashing: 

Pump down malfunction error (Stop).

D

-

LP

Flashing: 

Pump down malfunction error (Start-up).

D

-

D: 

     

Displays the message on the display

A: 

Activates the alarm relay (if available).

AKO-D1460x
AKO-D1461x
AKO-D1462x
AKO-D1463x
AKO-D1464x

GENERAL STATUS

Description

Values Min. Def. Max.

CnF

P10

Configuring digital input 1 (DI1)

0

= Off

1

=Door contact

2

=External alarm

3

=Severe external alarm

4

=Slave defrost

5

=Act. ECO mode by pushbutton

6

=Act. Fast Freezing 

7

= Low pressure switch *

8

=Remote defrost

9

=Act. ECO mode by switch

0

0

3

!

0

0

9

! !

P11

Configuring digital input 2 (DI2)

0

= Off

1

=Door contact

2

=External alarm

3

=Severe external alarm

4

=Slave defrost

5

=Act. ECO mode by pushbutton

6

=Act. Fast Freezing 

7

= Low pressure switch *

8

=Remote defrost

9

=Act. ECO mode by switch

0

0

3

!

0

0

9

! !

P12

Digital input polarity 1 

0

=Energised on closed contact, 

1

=Energised on open contact

0

0

1

! ! !

P13

Digital input polarity 2 

0

=Energised on closed contact, 

1

=Energised on open contact

0

0

1

! ! !

P14

Maximum start-up time after pump down

(Seg.)

0

0

120

!

P15

Maximum pump down time

(min.)

0

0

15

!

P22

Cold room light timer 

(min.)

0

0

999

!

EP

Exit to Level 1

! ! ! ! !

ACCESS AND INFORMATION CONTROL

Description

Values Min. Def. Max.

tid

L5

Access code (Password)

0

-

99

! ! ! ! !

PU

Program version (Information)

-

! ! ! ! !

Pr

Program revision (Information)

-

! ! ! ! !

EP

Exit to Level 1

! ! ! ! !

EP

Exit programming

! ! ! ! !

Level 1

Level 2

Accesories

AKO-D14918

The 

AKO-D14918 

programming  key  allows  you  to  quickly  and  easily  copy 

configured settings from one controller to another with the same functionality.

*

 

 AKO-D1464x / D-1464x-C.

P10/P11:

 Options available depending on the model.

Only available on

 Access to set point and programming

AKO-D1460x
AKO-D1461x
AKO-D1462x
AKO-D1463x
AKO-D1464x

FAN CONTROL (Evaporator)

Description

Values Min. Def. Max.

FAn

F0

Fan shut-down temperature as per probe 2 (if P4 

¹ 

1)

(ºC / ºF)

-50.0

*

99.0

! !

F1

Probe 2 differential (If P4 

¹ 

1)

(ºC / ºF)

0.1

2.0

20.0

! !

F2

Stop fans when stopping compressor 

0

=No, 

1

=Yes

0

1

1

! !

F3

Fan status during defrost: 

0

=Off; 

1

=On

0

*

1

! !

F4

Starting delay after defrost (if F3=0) 
Will only operate if it is higher than d9

(min.)

0

3

99

! !

F5

Stop fans on opening the door 

0

=No, 

1

=Yes

(Requires a digital input configured as port P10 or P11=1)

0

0

1

! !

EP

Exit to Level 1

! !

ALARMS CONTROL

Description

Values Min. Def. Max.

AL

A0

Configuration of temperature alarms: 

0

=Relative to SP; 

1

=Absolute

0

0

1

! ! !

A1

Maximum alarm probe 1 (must be greater than SP)

With NTC

(ºC / ºF)

A2

99.0

99.0

! ! !

With PTC

-

150

!

A2

Minimum alarm probe 1 (must be less than SP)

(ºC / ºF)

-50.0 -50.0

A1

! ! !

A3

Temperature alarm delay during start-up

(min.)

0

0

120

! ! !

A4

Temperature alarm delay after completion of a defrost

(min.)

0

0

99

! ! !

A5

Temperature alarm delay after reaching the value of A1 or A2

(min.)

0

30

99

! ! !

A6

External alarm / Severe external alarm delay when receiving digital input
signal (P10 or P11=2 or 3)

(min.)

0

0

120

! ! !

A7

Deactivation delay of the external alarm / Severe external alarm when the 
signal of the digital input disappears (P10 or P11=2 or 3)

(min.)

0

0

120

! ! !

A8

Show warning if defrost is terminated by time-out 

0

=No, 

1

=Yes

0

0

1

! !

A9

Alarm relay polarity

 

0

=Relay ON in alarm (OFF no alarm)

1

=Relay OFF on alarm (ON with no alarm)

0

0

1

!

!

A10

Temperature Alarm Differential (A1 and A2)

(ºC / ºF)

0.1

1.0

20

! ! !

A12

Door open alarm delay (if P10 or P11=1)

(min.)

0

2

120

! ! !

EP

Exit to Level 1

! ! !

GENERAL STATUS

Description

Values Min. Def. Max.

CnF

P0

Type of operation 

0

=Direct, Cold;

1

=Inverted, Heat

0

*

1

! !

P1

Delay of all functions on receiving electrical power

(min.)

0

0

255

! ! ! !

P2

Access code (password) functions

0

=Inactive; 

1

=Block access to parameters; 

2

=Keyboard lock

0

0

2

! ! ! ! !

P4

Selection of type of inputs

1

=1 Probe (S1+DI1+DI2)

2

=2 Probes (S1+S2+DI1+DI2)

3

=3 Probes (S1+S2+S3+DI1)

4

=2 Probes (S1+S3+DI1)

1

1

4

! !

P5

MODBUS address (Only AKO-D146xx-C)

1

1

255

! ! !

P6

Configuration of AUX relay

1

=Defrost / 2nd Defrost

2

=Alarm

3

=Light

4

=Pump down 

5

=Master Defrost

1

1

5

!

P7

Temperature display mode

0

=Whole in ºC

1

=One decimal in ºC 

2

=Whole in ºF

3

=One decimal in ºF

0

1

3

! ! ! ! !

P8

Probe to be displayed (as per parameter P4)

0

=visualization of all the probes in sequence; 

1

=Probe 1;

2

=Probe 2;

3

=Probe 3

0

1

3

! !

P9

Selection of probe type

0

=NTC;

1

=PTC

0

0

1

! ! !

Level 1

Level 2

AKO-D1460x
AKO-D1461x
AKO-D1462x
AKO-D1463x
AKO-D1464x

CONTROL

Description

Values Min. Def. Max.

rE

SP

Temperature Adjustment (Set Point)
(limits depending on probe type)

With NTC

(ºC / ºF)

-50.0

*

99.0

! ! ! !

With PTC

-

150

! !

C0

Calibrating probe 1 (Offset)

(ºC / ºF)

-20.0

0.0

20.0

! ! ! ! !

C1

Probe 1 differential (Histeresis)

(ºC / ºF)

0.1

2.0

20.0

! ! ! !

C2

Upper blocking of the set point 
(cannot be set above this value)

With NTC

(ºC / ºF)

C3

99.0

99.0

! ! ! !

With PTC

-

150

! !

C3

Lower blocking of the set point (cannot be set below this value)

(ºC / ºF)

-50.0 -50.0

C2

! ! ! !

C4

Type of delay for protection of the compressor:

0

=OFF/ON (since the last disconnection); 

1

=OFF-ON/ON-OFF (since the last shut-down /start-up)

0

0

1

! ! ! !

C5

Protection delay time 
(value of the option selected in parameter C4)

(min.)

0

0

120

! ! ! !

C6

Status of COOL relay with probe fault 

0

=OFF; 

1

=ON; 

2

=Average based on last 24 hours prior to probe fault; 

0

2

2

! !

Status of COOL relay with probe fault 

0

=OFF; 

1

=ON; 

2

=Average based on last 24 hours prior to probe fault; 

3

=ON-OFF as prog. C7 and C8 

0

2

3

! !

C7

Time relay ON in case of faulty probe
(If C7=0 and C8

¹

0,

 

the relay will always be OFF deenergised)

(min.)

0

10

120

! !

C8

Time relay OFF in case of fault of probe 1
(If C8=0 y C7

¹

0, the relay will always be ON energised)

(min.)

0

5

120

! !

C9

Maximum duration of fast freezing mode. (0=off)

(h.)

0

24

48

! !

C10

Change set point (SP) in fast freezing mode, when it reaches this point 
(SP + C10) returns to normal. (SP+C10 

³

 C3) (

0

=OFF)

(ºC / ºF)

0

-50.0 C3-SP

! !

C11

Length of inactivity at digital input to activate ECO mode
(Only if P10 or P11=1) (0=OFF)

(h.)

0

2

24

! !

C12

Change set point (SP) in ECO mode (SP+C12 

 

C2) (

0

=off)

£

(ºC / ºF)

0

2

C2-SP

! !

EP

Exit to Level 1

! ! ! ! !

DEFROST (If P0=0)

Description

Values Min. Def. Max.

dEF

d0

Defrost frequency (Time between two starts)

(h.)

0

*

96

! ! ! !

d1

Maximum defrost duration (

0

=defrost deactivated)

(min.)

0

*

255

! ! ! !

d2

Type of message during defrost:

0

=Currentl temperature;

1

=Temperature at start of defrost;

2

=Display dEF message 

0

2

2

! ! ! !

d3

Maximum duration of message (time added at the end of the defrost)

(min.)

0

5

255

! ! ! !

d4

Defrost end temperature (probe 2) (If P4 

¹ 

1)

(ºC / ºF)

-50.0

8.0

99.0

! !

d5

Defrost on equipment start-up

0

=NO, First defrost as per d0,

1

=YES, First defrost as per d6

0

0

1

! !

d6

Defrost start delay on equipment start-up

(min.)

0

0

255

! !

d7

Defrost type:

0

=Resistors, 

1

=Inverted cycle

0

0

1

! !

d8

Calculated time between defrost periods:

0

=Total actual time; 

1

 =Sum of times the compressor is on

0

0

1

! !

d9

Drip time at end of defrost (compressor and fans off) (if P4 

¹ 

1)

(min.)

0

1

255

! !

EP

Exit to Level 1

! ! ! !

Level 1

Level 2