AKO AKO-D1460 Series Скачать руководство пользователя страница 1

Keyboard

Installation instructions

1461H032 Ed.01

3

5

1

4

6

1

0

3

2 R
EV

.0

0 2
0

1

4

AKO ELECTROMECÁNICA 

, S.A.L.

Avda. 

Roquetes, 30-38

08812 

 Sant Pere de Ribes.

Barcelona 

 Spain.

Tel.: +34 902 333 145

Fax: +34 938 934 054

www.ako.com

We 

reserve the 

right to 

supply materials 

which may 

be slightly 

different from 

those 

described in 

our Data 

Sheets. Updated 

information on 

our web 

site.

60

41,5

94

125,5

35

ø max. 3,7

171

1

Installation

Wiring

Display

ECO mode ON

Program Mode

Stand-by mode ON

Fast Freezing mode ON

FAN relay ON

DEF relay ON

Light ON / 

2

 

RES relay ON

AUX relay ON

SET

SET

SET

SET

SET

Press for 5 seconds, allows changing the set point (SP). (Not available in thermometers)
Pressing for 10 seconds goes to the programming menu.
In the programming menu, go to the level displayed or accept the new value while setting a parameter.

Pressing for 5 seconds starts/stops defrosting. (Not available in thermometers)
The programming menu, allows you to scroll through the various levels or, during the setting of a parameter, to change the value.

Press for 5 seconds to start/stop Fast Freezing mode (rapid cooling). (Function available depending on the model).
The programming menu, allows you to scroll through the various levels or, during the setting of a parameter, to change the value.

Pressing for 5 seconds activates Standby mode, pressing for 2 seconds returns the equipment to normal mode. In Standby 
mode, the equipment performs no actions and only the indicator is displayed on the screen 

m

.

In the programming menu, go to the level displayed.

Pressing it for 1 second, activates or deactivates the cold room light (if P6=3). This function stays active although the unit is 
in the stand-by mode. (Function available depending on the model).
In the programming menu, exit without saving parameter, return to previous level or exit programming.

Operation

16 A

16 A

16 A

16 A

6 A

8 A

8 A

S3 / DI2

S3 / DI2

DI1

DI1

S2

S2

S1

S1

1

2

3

4

5

6

7

8

9

10

1

1
12

13

1

2

3

4

5

6

7

8

9

10

1

1
12

13

14

15

AKO-D1464x

AKO-D1463x

I max.:

16 A

I max.:

16 A

L

N

L

N

COOL

COOL

AUX.

AUX

FAN

FAN

DEF

DEF

AUX.

The probe and its cable should 

NEVER 

be 

installed  in  the  same  conduit  as  power, 
control or supply cables.

Start-up

AKO-D1461x / AKO-D1462x

On power-up, the equipment will start up in Wizard mode (InI / 1 
flashing), press

 

 

N

 or 

Q

 to select the most appropriate 

application and press 

SET

.

1

: Chilling

2

: AC

3

: Heat/Incubators

The wizard will configure the parameters of the equipment for the 
chosen application (see table).

AKO-D1463x / AKO-D1464x

On power-up, the equipment will start up in Wizard mode (InI / 1 
flashing), press 

N

 or 

Q

 to select the most appropriate application 

and press 

SET

.

1

: Chilling

2

: Frozen

3

: Fruits and vegetables

4

: Fresh fish

5

: Soft Drinks

6

: Bottle racks

7

: AC

The wizard will configure the parameters of the equipment for the 
chosen application (see table).

WARNING:

  The  default  parameters  by  type  of 

application have been defined for the most common 
applications. Check that these parameters are suitable 
for your installation.

WIZARD

SP

d0

d1

F0

F3

InI=1: Chilling

2

4

20

8

1

InI=2: Frozen

-18

4

20

0

0

InI=3: Fruits and Vegetables

10

4

20

30

1

InI=4: Fresh fish

0

4

20

8

1

InI=5: Soft Drinks

3

24

20

8

1

InI=6: Bottle racks

12

24

20

30

1

InI=7: AC

21

96

0

99

1

AKO-D14631:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14632:

230 V~ ±10%

50 / 60 Hz

AKO-D14632-C:

90-240 V~

50 / 60 Hz

AKO-D14641:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14642:

230 V~ ±10%

50 / 60 Hz

AKO-D14642-C:

90-240 V~

50 / 60 Hz

Tr +

Tr +

Tr -

Tr -

G

n

d

G

n

d

Modbus*

Modbus*

1

1

2

2

3

3

* Depending on model

2

2

2

3

4

COOL relay ON 

1

 

1

:In 

AKO-D1461x / D1462x, 

if P0=0

2

:In 

AKO-D1461x / D1462x, 

if P0=1

AKO-D1460x

AKO-D1461x

AKO-D1462x

AKO-D1463x

AKO-D1464x

AKO-D146xx-C

16 A

S1

S1

2

1

3

4

5

6

7

AKO-D1461x

AKO-D1461x

AKO-D14610:

230 V~ ±10%

50 / 60 Hz

AKO-D14612:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14610:

230 V~ ±10%

50 / 60 Hz

AKO-D14612:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14601:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14602:

230 V~ ±10%

50 / 60 Hz

AKO-D14621:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14622:

230 V~ ±10%

50 / 60 Hz

AKO-D14622-C:

90-240 V~

50 / 60 Hz

AKO-D14621:

120 V~ +8% -12%

50 / 60 Hz

AKO-D14622:

230 V~ ±10%

50 / 60 Hz

AKO-D14622-C:

90-240 V~

50 / 60 Hz

S1

2

1

3

4

5

6

AKO-D1460x

I max.:

16 A

I max.:

16 A

L

N

L

N

COOL

RES

16 A

16 A

Tr +

Tr +

Tr -

Tr -

G

n

d

G

n

d

Modbus*

Modbus*

6 A

6 A

DI2

DI2

DI1

DI1

S1

S1

1

1

2

2

3

3

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

13

13

14

14

15

15

AKO-D1462x

AKO-D1462x

I max.:

16 A

I max.:

16 A

L

N

L

N

COOL

ALARM

ALARM

RES

15

16

17

18

19

GSM ALARM
AKO-52042

15

16

17

18

19

GSM ALARM
AKO-52042

Mode: COLD

(P0=0)

Mode: COLD

(P0=0)

Mode: HEAT

(P0=1)

WIZARD

SP

d0

d1

P0

InI=1: Chilling

0

6

20

0

InI=2: AC

21

0

0

0

InI=3: Heat/Incubators

37

-

-

1

16 A

2

1

3

4

5

6

7

Mode: HEAT

(P0=1)

Warnings

-Using the equipment without following the manufacturer's instructions may affect the device's safety requirements. To ensure that the 

device operates correctly, only probes supplied by AKO should be used. 

-The unit must be installed in a location protected from vibrations, water and corrosive gases, where the ambient temperature does not 

exceed that shown in the technical data.

-To ensure a correct reading, the probe must be situated in a location without any external heat influences except for the temperature which 

is being measured or controlled.

-The power supply circuit must be provided with a main switch rated at at least 2 A, 230 V, located close to the equipment. The cables will 

enter through the back and should be type H05VV-F or H05V-K. 

2

-The gauge will depend on local regulations, but should in no case be less than 1 mm .

2

-Connecting wires for the relay contacts should be sized 2.5 mm .
-Between -40 ºC and +20 ºC, if the probe NTC is prolonged till 1.000 m with a mínimum of cable 0,5 mm², the maximum deviation will be of 

0,25 ºC (extension cable for probe ref. 

AKO-15586

)

NOTE: 

Equipment not compatible with 

AKO-14917 

(external communication module) and 

AKO-14918 

(programming key)

GB

AUX Relay

Function as per 

parameter P6

S1:

 Probe 1, temperature in the chamber or cabinet.

S2:

 Probe 2, defrost.

S3:

 Probe 3, temperature of product / 2nd defrost.

DI1/DI2:

 Digital Input 1 / Digital Input 2.

User Manual available on

http://www.ak

o.com/w4pu/page/qr/?qrcode=AK

ODOC0051