![AKO-Agrartechnik BA-1365 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/ako-agrartechnik/ba-1365/ba-1365_instruction-manual_2886575005.webp)
Version : 2021.1
3
Specific Operating Instructions
-EN-
1
Commutateur rotatif (0-1)
2
Control lamp
9V battery
3
Control lamp
fence
4
Earth connection
5
Fence connection
6
Earth rod / holder
7
Earth connecting cable
(Connection between earth
connection of device and earth
rod!)
a.) Installation
Assemble the earth electrode (6) as shown in the above figure; screw the earth connecting cable (7) onto the earth electrode with the
fastening screw. Drive the earth electrode into the ground as far as the angle brackets and then place the appliance in upright position
in the screwed-on angle brackets, see above figure.
b.) Functional description of the appliance
Open the appliance by pressing the catch hook on both sides and simultaneously raising the lid. Insert the battery into the receptable
and connect to the appliance. Close the lid. Operate the appliance only in vertical position and with the catch hook clicked firmly into
place. Put the appliance into service
without
fence and earth. If the indicator light (3) flashes green, the appliance is ready for use. If it
flashes red, check the 9V battery for correct voltage (min. 6V). If the indicator light does not
flash, check the battery for correct polarity
or have the appliance checked by a technician.
c.) Functional description with connected fence system ( fence + earth )
Control lamp Fence (POS.3)
0V - 2500V
Check fence system
(error sources operating instructions Figure2; p. 5)
>2500V
>3500V
Fence Tension OK
>4500V
>6000V
Control lamp 9V battery (POS.2)
6,5V - 7,0V
|
|
|
|
|
|
Please exchange it soon
6,0V - 6,5V
|
|
|
|
|
|
Please swap
0,0V - 6,0V
|
|
|
|
|
|
Device is switched off – No fence pulse
Control lamp 12V battery (POS.2)
11,6V - 12,0V
|
|
|
|
|
|
Please exchange/ reload it soon
11,4V - 11,6V
|
|
|
|
|
|
Please swap
0,0V - 11,4V
|
|
|
|
|
|
Device is switched off – No fence pulse
If the control lamp (3) should blink faster than 1x per second, the device must be switched off immediately and inspected by a specialty
technician before re-commissioning.
The device provides 12V operation with total discharge protection. This is indicated by red blinking of the pilot lamp. The 12V
accumulator voltage should therefore be checked at regular intervals with a highly accurate measuring instrument (see battery and
accumulator maintenance in the enclosed instruction manual).
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in accordance with
the conditions of use, at least once per day.
-
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, maintenance of battery and
accumulator, warranty terms and conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
This
energizer
shall
not
be
used
as
an
animal
trainer
(inside
a
barn).
Possible current sources:
- 9 /12 Volt
- special 230 Volt mains-adapter,
for indoor use only
(Art.-Nr.: 371016)
1
3
2
4
5
7
6
Содержание BA-1365