![AKM AK5366 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/akm/ak5366/ak5366_manual_2886258004.webp)
[AKD5366]
<KM073601>
2007/04
- 4 -
DIP Switch set up
[SW1] (MODE1): Setting the evaluation mode for AK5366
ON
is
“H”,
OFF
is
“L”.
Default
is
all
“L”.
No. Name
OFF
(“L”)
ON
(“H”)
1
I2C
3-wire Control
I2C Control
2 CAD0
Fixed
to
“L”
3 CAD1
Fixed
to
“L”
4 DIF
Fixed
to
“L”
5 SEL2
6 SEL1
7 SEL0
See Table 2
8 ALC
Fixed
to
“L”
Table 1. Mode Setting of AK5366
SEL2 SEL1 SEL0
Input
Selector
OFF
OFF
OFF
LIN1 / RIN1
Default
OFF
OFF
ON
LIN2 / RIN2
OFF
ON
OFF
LIN3 / RIN3
OFF
ON
ON
LIN4 / RIN4
ON
OFF
OFF
LIN5 / RIN5
Table 2. Input Selector
[SW3] (MODE2): Setting the evaluation mode for AK4103
ON
is
“H”,
OFF
is
“L”.
Default
is
all
“L”.
No. Name
OFF
(“L”)
ON
(“H”)
1
DIF
24bit, MSB justified
24bit, I
2
S Compatible
2 CKS1
3 CKS0
See Table 4
Table 3. Mode Setting of AK4103
Mode CKS1 CKS0 MCLK
fs
0 OFF OFF 256fs
∼
96kHz
Default
1 OFF ON N/A N/A
2 ON OFF 512fs
∼
48kHz
3 ON ON 384fs
∼
48kHz
Table 4. MCLK Frequency Setting of AK4103
The function of the toggle SW
Upper-side is “H” and lower-side is “L”.
[SW2] (PDN): Resets the AK5366 and AK4103. Keep “H” during normal operation.
[SW4] (SMUTE): Soft mute of AK5366.