AKM Confidential
AK2571
OFFSET
adjustment
Adjusted by AKM
E_MON_SET 4
MON-DAC
output
set
1
1101
Refer table 6-1
E_STATUS_SET 3 STATUS
MON
output set
1
1101
Refer table 6-2
E_ALM_SHUTDW
2
ALM output set
1
1110
0x: ALM enable
10: Fix not active
polarity
11: Fix active polarity
E_ALM_POL
1
ALM polarity set
1
1110
0: ALM detect “H”
1: ALM detect “L”
E_OPALM_SET 3
OPALM
threshold
set
1
1110
000: 1/2, 001: 1/3
010: 1/4, 011: 1/5
100: 1/6, 101: 1/8
E_TIMER_SET 2
TIMER
ALM
count
period set
1
1111
00: 8s, 01: 16s
10: 32s, 11: 64s
E_INI_CTRL_USR 8 Start up sequence
set
2 01 11 1010 Refer
5.2.2
E_APC_CNT_CTRL_
USR
8 APC Count-up
operation set
2
1010 Refer
5.2.2
E_FIX_CTRL_USR 8 Normal operation
set
2
1011 Refer
5.2.2
E_LK_TMPRT_WIN 8
Window set for ATC
Lock window
1100
0.03
°
C/LSB
E_LK_CNT_SET
2
ATC Lock period set
1100
00: 2s, 01: 4s,
10: 8s, 11: 16s
E_PID_D 8
PID
differential
parameter
1101
Refer Table 4-3
E_PID_P 8
PID
proportion
parameter set
1101
Refer Table 4-3
E_PID_I 8
PID
integration
parameter set
1101
Refer Table 4-3
E_PID_MAX 6
PID
control
maximum value set
1101 6bits MSB of PID
absolute control value
(13bits)
E_PIDALM_SET
8
PIDALM
set
1111 8bits MSB of PID
absolute control value
(13bit)
E_PID_INACT_SET
8 PID not sense
window set
1111 8bits LSB of PID
absolute control value
(13bits)
USER program area
96
10
11
1010
|
1111
AKM adjust area
96
Start up sequence
operation set
11 11 1010
|
1111
Don’t touch the data.
Table 7-7 Common data addresses
<Rev. 0.6E Preliminary> -33-
2001/11