Akku Power 7S2P Скачать руководство пользователя страница 7

5

7

LED 

combination

LED 

combination

number

Description

16

Load overcurrent 1

17

Load overcurrent 2

18

Charge overcurrent

19

Short circuit

20

Temperature not OK

Table 6

: Error indicator

State of health

If the usable capacity of the battery is < 60% of the installed capacity (Ah), the SOH code will be displayed every time the battery comes out of the sleep 

mode. Once the SOH code is shown on the display the user should consider buying a new battery. 

LED 

combination

LED 

combination 

number

Description

21

State of Health SOH < 60% all 4 LEDs blinking for 10 sec

Table 7

: State of Health

 GB

Содержание 7S2P

Страница 1: ...SAFETY INSTRUCTIONS Li ION DT2 Battery 7S3P 25 2V 9 0Ah 226 8Wh 7S2P 25 2V 5 0Ah 126 Wh IDEX Fire Safety www akku power com...

Страница 2: ...2 GB 3 8 D 9 14 Please scan for more languages...

Страница 3: ...ush or throw the battery pack DO NOT put the battery pack into a microwave or high pressure container Never expose batteries to microwaves or high pressure DO NOT open a battery pack for any reason If...

Страница 4: ...ents avoiding contact with other items or conductive materials that may cause damages or short circuits on the pack If this is not guaranteed please reconsider storing location of the battery pack or...

Страница 5: ...ent fire explosion may follow depending on the circumstances If a battery burns the vapors can irritate eyes skin and the respiratory tract If chemicals leak follow the instructions below Inhalation C...

Страница 6: ...ccurrence and will be displayed until the query button is pressed again The BMS will store the last 3 error codes All possible LED combinations are listed in table 2 to table 7 LED combination LED com...

Страница 7: ...of health If the usable capacity of the battery is 60 of the installed capacity Ah the SOH code will be displayed every time the battery comes out of the sleep mode Once the SOH code is shown on the d...

Страница 8: ...urrent Charging current too high Check battery on another charger and after minimum 30 sec the error should be gone If the error persists with the second charger contact your dealer otherwise send in...

Страница 9: ...he Verformung der Zelle besch digt Der Separator wird durch mechanische Einwirkungen besch digt die z B durch eine Tiefentladung der Zelle verursacht werden Herzlichen Gl ckwunsch D 9 VORSICHTSMASSNAH...

Страница 10: ...die Batterie auf sichere Weise zu verwenden d rfen das Batterieladeger t nicht ohne Aufsicht oder Anweisung eines Fachmanns verwenden Beachten Sie unbedingt die minimale und die maximale Lade tempera...

Страница 11: ...ktrischer Verwendung die zu einer Aktivierung der Sicherheitsventile und oder einer Ruptur des Akkugeh uses f hrt Abh ngig von den Umst nden kann es zu einem Elektrolyt Austritt oder zu einer Reaktion...

Страница 12: ...zeigt Wenn der Akku nicht auf dem Ger t oder auf dem Lader steckt wird der Ladezustand SOC nach Dr cken der LED Taste f r 25 Sek angezeigt Der Ladezustand erlischt nach der angegebenen Zeit oder nach...

Страница 13: ...cher alle LEDs f r 1 5 Sek ausgehen Das sollte dem Benutzer helfen einfach und schnell die einzelnen Fehlercodes zu unterscheiden LED Kombination LED Komb Nr Beschreibung 16 berstrom Entladung 1 17 be...

Страница 14: ...m ist zu hoch berpr fen Sie den Akku eines anderen Ladeger ts und nach mindestens 30 Sekunden sollte der Fehler behoben sein Wenn der Fehler beim zweiten Ladeger t weiterhin besteht wenden Sie sich an...

Отзывы: