![AkitikA PR-101NR Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/akitika/pr-101nr/pr-101nr_assembly-manual_2886095043.webp)
Page 43 of 68
R21
4K02
Yellow, black, red, brown, brown
R22
4K02
Yellow, black, red, brown, brown
R23
4K02
Yellow, black, red, brown, brown
R24
4K02
Yellow, black, red, brown, brown
R61
NL
NL means not loaded
R65
NL
NL means not loaded
Install the Small Capacitors
Now we’ll install the following small capacitors. If you have a lead-bending jig, use the
0.4” spacing:
Designation
Value
Description
Done
C6
100p
COG, marked 101K
2
C7
100p
COG
C8
100p
COG
C9
100p
COG
C10
100p
COG
C11
100p
COG
Install the Diodes
If you’re using a lead-bending jig:
Use a 0.45” span for the 1N4004 diodes
Use a 0.40” span for the 1N4148 diodes
Install the diodes correctly. Make sure to match the banded end of the diode
to the banded end of the diode’s silk-screen.
Designation Value
Description
Done
D1
1N4004
1 Amp 400 PIV diode
D2
1N4004
1 Amp 400 PIV diode
D3
1N4004
1 Amp 400 PIV diode
D4
1N4004
1 Amp 400 PIV diode
D5
1N4004
1 Amp 400 PIV diode
D6
1N4004
1 Amp 400 PIV diode
D7
1N4004
1 Amp 400 PIV diode
D8
1N4004
1 Amp 400 PIV diode
D9
1N4004
1 Amp 400 PIV diode
D10
1N4004
1 Amp 400 PIV diode
2
There’s also a line that says K1G, but you need even more magnification to see that!