akira CT-14TA9CP Скачать руководство пользователя страница 8

 

 
 

Model No: CT-14TA9

CP

                      

Version 1.0

 

8

10.10. Use strong and weak signal to check the colour picture condition. After adjust the signal 

level to 35-40 dB and the colour should not gone. The picture and sound must be OK. At 60 

dB the picture should not have snow noise.  

10.11. Ensure the factory mode setting are set. Set-off the factory mode function and last switch    

off the TV set. 

10.12. All the “NG” sets must send for repairing and recording for reference. 

10.13. Check the AV input and output the picture and sound must be OK. 

 

11. 

Reliability Aging Test:

 

11.1. 1

st

 lot of production sets. Sampling 20 sets for aging 7 days continues test with colour signal 

in. Normal production sets must be age for 1 day. 

 

12. 

Mechanical Inspection:- 

12.1. Inspect all glue are firmly placed. 

12.2. Check all screws are tightened, no missing and loose. 

12.3. Check all the connectors are fully located onto the chassis base. 

12.4. Check all the safety components are firmly located onto the chassis and no damage. 

12.5. The TV internal side should not see any excess metal materials. 

12.6. Check all the cable and wire are OK in-used. 

12.7. Check the FBT and switching transformers not high mounting. The big capacito are not 

slanting and high mounting. 

 

13. 

High Potential Testing

:- 

13.1. Set the mega-meter is set in position.(Insulation tester) 

13.2. Set the meter to DC500V. 

13.3. Use the meter probe onto the tuner body and the power cord on connector socket. 

13.4. Switch on the button and test the insulation performance and the reading at 2/3 position. 

13.5. Insulation spec must over 9.0 Mohm. if not reject. 

 

Note: Everyday work check the high pot. Condition as 3100V, 10 mA, 5 sec are OK. 

 

14. 

Safety Check

:- 

14.1. High voltage checking. Use high pot tester and set the tester to 3100V, 10mA and ensure the 

AC/DC switch is in AC position. Set the tester to 10mA and timer to 5 sec. 

14.2. Checking methods. 

14.2.1.  connect the power cord into power socket. 

14.2.2.  the high pot tester gun pointed at metal part of  TV set body. 

14.2.3.  switch on the switch to test the high electric power. 

14.2.4.  connect with high voltage within 5 second and remove the tester gun point. 

 

(B) CTV SET ALIGNMENT  -  FACTORY SERVICE MODE 

 

1. 

Enter” and “Leave” the Factory mode adjustment methods

1.1.  Enter factory password: (use normal Remote control unit) 

1.1.1.  Set TV as RF condition and press remote control “PROG” key and follow by “6”, “4”, “8”,  

“3” 

1.1.1.1. Repeat the same step of “1.1.1.” to enter into “White Balance” adjustment 

condition 

1.1.1.2. Repeat the same step of “1.1.1.” to enter into “Factory mode” adjustment 

condition 

1.1.1.3. Repeat the same step of “1.1.1.” to enter into “Factory mode” setting condition 

1.1.1.4. Repeat the same step of “1.1.1” to leave the factory mode function 

 

 

 

 

 

 

  

 

Содержание CT-14TA9CP

Страница 1: ...C C Co o ol l lo o ou u ur r r T T TV V V S S Se e er r rv v vi i ic c ce e e M M Ma a an n nu u ua a al l l...

Страница 2: ...Model No CT 14TA9CP Version 1 0 2 CHASSIS SS1 MODEL CT 14TA9CP...

Страница 3: ...Model No CT 14TA9CP Version 1 0 3 CONTENTS Specifications 4 X Ray Radiation Precaution 5 Safety Precaution 5 Product Safety Notice 5 Alignment Instructions 6 Schematic Diagram 12...

Страница 4: ...B Picture Tube 14 37cm diagonal Ext Antenna 75 Ohm Coaxial Cable Ext In Out Audio Video in out Speakers 5W x 2 Volts A AC100 260V 50 60Hz R N CP AC150 260V 50 60Hz Power Consumption 14 65W Dimension 1...

Страница 5: ...ervice to avoid possible shock hazard 2 Always discharge the picture tube anode to the CRT conductive coating before handling the picture tube The picture tube is highly evacuated and if broken glass...

Страница 6: ...meter with LED display 4 digits 1 5 Factory mode remote control unit 2 Channels setting required Channel 1 Monoscope pattern PAL DK Music Channel 7 Half Colour Bar pattern PAL I Modulation Channel 12...

Страница 7: ...ustment 8 1 Receive crosshatch pattern use factory mode remote control to press factory mode key for adjustment Using CH keys for V Size and V Line selection 8 2 Use V keys to adjust the picture line...

Страница 8: ...3 1 Set the mega meter is set in position Insulation tester 13 2 Set the meter to DC500V 13 3 Use the meter probe onto the tuner body and the power cord on connector socket 13 4 Switch on the button a...

Страница 9: ...ey and V V key for selection and adjustment 1 Setting of company logo 1 1 Switch on the TV set and set the TV in AV mode Press Remote control DISP key and the TV screen will display AV and follow by p...

Страница 10: ...Vertical position 24 23 23 25 0 63 07 V SC Vertical SC adjust 0 0 0 0 31 08 NT V SIZE NTSC Vertical size 6 0 0 0 31 32 09 NT V LINE NTSC Vertical line 1 0 0 0 15 16 10 NT V POST NTSC Vertical positio...

Страница 11: ...trap filter control 1 1 1 0 3 17 VIF SYS SW VCO setting 1 0 0 0 0 7 18 VIDEO LEVEL Video output adjustment 7 7 7 0 7 19 FM LEVEL Sound output adjustment 16 16 16 0 31 20 POWER OPTION Power on selecti...

Страница 12: ......

Отзывы: