31
Model No: AC-S7CK_S7HK
Version 1.0
l
In case of the outdoor unit is installed upper position of the indoor unit.
F
Tape the piping and connecting cable from down to up.
F
Form the piping gathered by taping along the exterior wall and the trap is re-
quired to prevent water from entering into the room.
F
Fix the piping onto the wall by saddle or equivalent.
l
Connecting the cable to the indoor unit as shown in the OPERATING AND
INSTALLATION INSTRUCTIONS MANUAL.
6. AIR PURING OF THE PIPINGS AND INDOOR UNIT
l
Air purging preparation
F
Remove the caps from the 2-way and 3-way valves.
F
Remove the service-port cap from the 3-way valve.
F
To open the valve, turn the valve spindle of 2-way valve counter-clockwise ap-
proximate
90
°°
and hold it there for
5 seconds
, then close it.
F
Caution
: Do not leak the gas in the air during air purging.