
29
Model No:
AC-S10CK_S10HK
Version 1.0
5. CHECKING THE DRAINAGE AND CONNECTING THE CABLE TO INDOOR
UNIT
l
Checking the drainage
1) Remove the grille from the cabinet
F
Set the up-and-down air direction louver to open position(horizontally) by finger
pressure.
F
Remove the screw caps and the securing screws.
F
To remove the grille, pull the lower left and right side of the grille toward you
(slightly titled) and lift it straight upward(Two tabs on the top inside edge of the
grille are clear of their slots).
2)
Check the drainage
F
Pour glass of water on the evaporator.
F
Ensure if water flows from drainage hose of indoor unit.
l
Form the piping
F
Wrap the connecting portion of indoor unit with the insulation material and se-
cure it with two plastic bands (for the right piping).
Содержание AC-S10CK
Страница 24: ...24 Model No AC S10CK_S10HK Version 1 0 F Cut the cable a 1 5m longer than the pipe length ...
Страница 50: ...50 Model No AC S10CK_S10HK Version 1 0 2 Exploded view of outdoor unit for model AC S10CK ...
Страница 51: ...51 Model No AC S10CK_S10HK Version 1 0 3 Exploded view of outdoor unit for model AC S10HK ...