akira AC-FR30HK Скачать руководство пользователя страница 8

       

                                                             

 

 

8

 

 
Model No: AC-FR30HK 
Version 1.0 
 

   

 
 

Indoor temperature

Indoor temperature

Target temperature

Target temperature

21

¡

æ

 or below

26

¡

æ

 or below

     22

¡

æ

     22

¡

æ

     26

¡

æ

     26

¡

æ

Over 26

¡

æ

Over 26

¡

æ

21

¡

æ

¡

æ

-26

Operation mode

Operation mode

HEATING

DRY

DRY

 Room temperature 
decrease 1.5

¡

æ

 after

operate for 3 minutes

 Room temperature 
decrease 1.5

¡

æ

 after

operate for 3 minutes

COOLING

COOLING

Heat pump models 

Cooling only models

 
SMART button is ineffective in SUPER mode. Temperature and airflow are controlled automatically 
in SMART mode. However, a decrease or rise of up to 2 

  can be set with the remote controller 

according to the following table if you still feel uncomfortable. 
 

High

High

High

High

Low

Low

Low

Low

Your feeling

A decrease or increase up to 2  can be set in SMART mode

¡

æ

button

adjustment procedure

A  rise up to 
2  can be set

¡

æ

A decrease  up 

to 2  can be set

¡

æ

 Uncomfortable
 because of 

 unsuitable air
 flow volume.

 Uncomfortable

 because of 
 unsuitable flow 

 direction.

Press once to  lower the 
set temp by 1

Press twice to  lower the 
set temp by 2

Indoor fan speed alternates among
High, Medium and Low each time this 

button is pressed. 

Press it once, the vertical adjustment 

louver swings to change vertical airflow 
direction. Press it again, swings stops.

For horizontal airflow direction, please
refer to the previous page for details.

Press once to  raise the 

set temp by 1 

Press twice to raise the 
set temp  by 2 .

¡

æ

Slightly warmer

Slightly cooler

¡

æ

¡

æ

¡

æ

FAN

 
 

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Содержание AC-FR30HK

Страница 1: ...Air Conditional Service Manual http splitoff ru tehn doc html...

Страница 2: ...2 Model No AC FR30HK Version 1 0 Model AC FR30HK http splitoff ru tehn doc html...

Страница 3: ...3 Model No AC FR30HK Version 1 0 CONTENTS SPECIFICATIONS 4 FUNCTION DETAILS 6 EXPLODED VIEW PART LIST 14 REFRIGERATION DIAGRAM 18 WIRING DIAGRAM 19 http splitoff ru tehn doc html...

Страница 4: ...20 240V 1P 50Hz Cooling 13 5 Heating 12 5 Rated Current A PTC Heater 8 7 LRA A 65 High 50 Indoor Unit Low 40 Noise Level dB A Outdoor Unit 58 System Refrigerant g R22 Compressor type Scroll Compressor...

Страница 5: ...es PTC Heater Yes Other Indoor Unit 540x1765x275 Dimensions WxHxD mm Outdoor Unit 832x702x380 Indoor Unit 46 Net Weight Kg Outdoor Unit 66 Indoor Unit 660x1890x420 Packing Dimensions WxHxD mm Outdoor...

Страница 6: ...High Medium Low FAN button is ineffective in DRY mode Indoor fan motor operates according to the following circle while pressing the button in other modes Auto High Medium Low 3 SWING LOCK button Pre...

Страница 7: ...utton for the first time h is displayed and the TIMER symbol is flashed on the LCD Pressing the button once to increase the preset time 0 5 hour with 10 hours or 1 hour over 10 hours Timing range is f...

Страница 8: ...eel uncomfortable High High High High Low Low Low Low Your feeling A decrease or increase up to 2 can be set in SMART mode button adjustment procedure A rise up to 2 can be set A decrease up to 2 can...

Страница 9: ...Using SWING LOCK button to set various angles of flow or specific angle as you like Pressing SWING LOCK button once the vertical adjustment louver will swing up and down automatically Pressing the SWI...

Страница 10: ...nslates tiny speed LCD displays SLEEP symbol If air inlet temperature of indoor unit is equal to or more than 26 in cooling mode setting temperature is invariable otherwise setting temperature rises 0...

Страница 11: ...ing hour when A C is normal LCD displays trouble code if protection function appears Operation Mode 1 COOLING MODE When the COOLING mode operation is selected without setting temperature after power s...

Страница 12: ...tor speed and airflow direction can be adjusted preventing cold air function starts If indoor pipe temperature is below 30 indoor fan motor speed switches to tiny automatically if indoor pipe temperat...

Страница 13: ...perates according to setting mode airflow direction can be adjusted compressor and outdoor fan motor stall Temperature drop Set temperature 1 Compressor off Compressor on Compressor off Compressor on...

Страница 14: ...14 Model No AC FR30HK Version 1 0 EXPLODED VIEW AND PART LIST INDOOR UNIT http splitoff ru tehn doc html...

Страница 15: ...ntroller assembly 8140166 1 20 Mid pitman 12013019 1 21 Horizontal vane 1201378 6 22 Side pitman 12013018 4 23 Transverse pitman 12013022 1 24 Rocker 12013006 1 25 Vertical vane 12013020 5 26 Air outl...

Страница 16: ...16 Model No AC FR30HK Version 1 0 OUTDOOR UNIT http splitoff ru tehn doc html...

Страница 17: ...34 1 16 Power wire nether Clamp 110963 1 17 Power wire upper Clamp 1109147 1 18 Terminal 5P3 150288 1 19 Terminal 4P2 15023004 A 1 20 Terminal 2U 150217 A 1 21 Fan capacitor 14113058 1 22 AC contactor...

Страница 18: ...Indoor unit R22 flowing direction at cooling R22 flowing direction at heating 3 way valve 2 way valve Reversing valve R22gas liquid separator Compressor Outdoor fan motor Conden ser R22 filter Capilla...

Страница 19: ...19 Model No AC FR30HK Version 1 0 WIRING DIAGRAM Indoor Unit http splitoff ru tehn doc html...

Страница 20: ...20 Model No AC FR30HK Version 1 0 Outdoor Unit http splitoff ru tehn doc html...

Страница 21: ...http splitoff ru tehn doc html...