![Akiles FlexiCloser Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/akiles/flexicloser/flexicloser_operation-manual_2885899003.webp)
Micro-Adjust “+”
Reset / Return
START
Control Panel
Micro-Adjust “-”
3
1. Different brands of wires might be produced with different materials and/or different wire
forming machines, thus having different flexibilities (wire closing memories). To ensure a
perfect wire closing result with all types & brands of wires, your FlexiCloser is equipped with
a Micro-Adjust Feature.
2. The Micro-Adjust Feature allows the operator to adjust the closing distance for each wire size
independently. To make an adjustment on a particular wire size, the operator should first place
such wire by itself (without sheets) into the closing channel, and press START to close it. Then,
take out this closed wire and inspect the closing result.
3. If your wire is UNDER-CLOSED (narrow & wide loops not touching each other, pages can fall out),
press “-” button on the Control Panel to reduce the closure distance.
The available selection ranges are:
a. For Smaller Wires (3/16” – 9/16”): 0.3 – 3mm (0.3mm per each adjustment)
b. For Larger Wires (5/8” – 1-1/2”): 0.6 – 6mm (0.6mm per each adjustment)
Try closing another wire of the same size, and inspect the closing result again. The wire should be
properly closed once the correct adjustment has been reached.
4. If your wire is OVER-CLOSED (narrow & wide loops overlapping each other too much, wire is
crushed), press “+” button on Control Panel to increase the closure distance.
The available selection ranges are:
a. For Smaller Wires (3/16” – 9/16”): 0.3 – 3mm (0.3mm per each adjustment)
b. For Larger Wires (5/8” – 1-1/2”): 0.6 – 6mm (0.6mm per each adjustment)
Try closing another wire of the same size, and inspect the closing result again. The wire should be
properly closed once the correct adjustment has been reached.
5. Memory settings will not be erased even if the main power switch is turned off, or power cable
unplugged. Therefore, the operator does not need to re-adjust settings for each job.
6. Master Memory Reset: If the operator wishes to erase all memory settings and bring the closing
distance of all wire sizes back to the factory default, simply turn on the machine, and HOLD the R
button for 3 seconds. The LCD display will show “CL” and all memory settings will then be erased.
7. Individual Memory Reset: If the operator wishes to erase the memory setting for only one type of
wire, simply close that specific wire, and then HOLD the R button for 3 seconds. The LCD display
will show “CL” and that specific memory setting will be erased.
MICRO-ADJUST FEATURE
Closed Wire
(Side View)
Closed Wire
(Top View)
Perfect
Closure
Under-
Closed
Over-
Closed