Input transformer with no center tap (floating):
Standard values for Rv or 2 x Rv:
V
s
R
v
2 x R
v
12 V ±2 V
330 ohms
680 ohms
24 V ±2 V
680 ohms
1200 ohms
48 V ±4 V
3300 ohms
6800 ohms
In order to preserve symmetry, use 2 x Rv resistors with a maximum toler-
ance of 0.5% only.
If the amplifier inputs are single-ended (grounded) or have no input trans-
formers, wire either capacitors or optional transformers into the audio lines
to prevent any current leakage into the input stage.
Adding Phantom Power to Unbalanced Amplifier Inputs
Cleaning
To clean the metal surfaces, use methylated spirits or alcohol.
Standard Accessories
H 100
shock mount
Optional Accessories
B 18
battery power supply
MK 9/10
10-m audio cable with 3-pin XLR connectors
N 62 E
AC power supply for two microphones
N 66 E
AC power supply for six microphones
PF 100
studio pop filter
SA 41/1
stand adapter
ST 102 A floor stand
ST 200
heavy floor stand
W 414
external windscreen (supplied with the C 414 B-ULS)
6