Preliminary
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Value
Item Symbol
Min. Max.
Unit Note
Storage Temperature
T
ST
-20 +60 ºC
(1)
Operating Ambient Temperature
T
OP
0 +50
ºC
(1),
(2)
Shock (Non-Operating)
S
NOP
-
50 G
(3),
(5)
Vibration (Non-Operating)
V
NOP
-
1.0 G
(4),
(5)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta
≦
40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c)
No
condensation.
Note (2) The maximum operating temperature is based on the test condition that the surface temperature of
display area is less than or equal to 60 ºC with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in final product design to prevent the surface temperature of
display area from being over 60 ºC. The range of operating temperature may degrade in case of improper
thermal management in final product design.
Note (3) 11 ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 500 Hz, 10 min, 1 time each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
Storage Range
10
20
60
40
80
-40
-20
0 20
40
60
80
100
90
Temperature (ºC)
Operating Range
Relative Humidity (%RH)
72ˋ
Содержание LCT2765TD
Страница 35: ... 4ˋ ...
Страница 36: ...IC DESCRIPTION MT8205G AT24C02 MX29LV160BBTC LP2996 AZ1117 H WM8776 MX232A ISAV330 5ˋ ...
Страница 44: ...37 75 ...
Страница 98: ...Preliminary 11 MECHANICAL CHARACTERISTICS CHI MEI 奇美電子股份有限公司 97ˋ ...
Страница 99: ...I Preliminary 奇美電子股份有限公司 CHI MEI 98ˋ ...
Страница 101: ...100ˋ ...