Installation Safety Instructions (Cont.)

The refrigerant used in this air conditioner, R32, is an odourless hydrocarbon 

gas with a

 high level of environmental compatibility, with significantly lower

 global 

warming potential (GWP) and a zero ozone depleting potential (ODP). While R32 

is flammable and can explode under certain conditions, there will be no risk of 

burning and explosion if the air conditioner is installed correctly by a professional 

installer following all instructions and safety advice in this installation manual.  

Important safety precautions concerning refrigerant R32

WARNING: Combustible & Dangerous

This symbol alerts you to take care as the appliance contains 

a flammable refrigerant: R32 (difluoromethane).

 

Take extra care 

when installing the unit and when carrying out maintenance.

• Do not expose the appliance to high heat, sparks and open flames. Do not 

pierce or burn the appliance. 

• The appliance shall be stored in a room without continuously operating 

sources, such as open flames, an operating ignition gas appliance or an 

operating electric heater.

• This air conditioner has been fully charged with refrigerant at the factory. Should 

a recharge of refrigerant become necessary, it may only be recharged by a 

professional installer. 

• Maintenance must only be carried out by properly qualified, authorised 

personnel. If the appliance requires maintenance or service, please contact our 

after sales support centre. 

The maintenance technician must do a safety 

inspection before carrying out any maintenance work. 

They must strictly 

comply with all instructions in this installation manual and all relevant provisions 

of gas-related local laws and regulations.

• It is necessary to operate the machine under a controlled procedure in order 

to ensure that any risk arising from the combustible gas or vapour during the 

operation is reduced to a minimum. 

Read the 

user manual

Read the 

installation manual

• The room in which this air conditioner is installed must be larger than 15m

in 

size. (This air conditioner is suitable for cooling/heating a room of 30–35m

2

.)

Please refer to tables 1 and 2, opposite, for the total weight of the filled 

refrigerant and the room area requirements.

Содержание AK-T51R32

Страница 1: ...WARRANTY This unit must be installed by a registered licensed installer as required by Government regulations INSTALLATION MANUAL Model Number AK T51R32 5 1kW Reverse Cycle Inverter Split System Air...

Страница 2: ...00 886 649 AUS 0800 836 761 NZ info tempo org Contents 03 Installation Safety Instructions 08 Product Overview 11 Selecting the Installation Place 13 Installation 21 Information for the Installer 26 O...

Страница 3: ...s to that stamped on the rating plate Keep the switch or power plug clean Check and ensure that the socket is suitable for the plug The appliance must be fitted with means for disconnection from the s...

Страница 4: ...y operating sources such as open flames an operating ignition gas appliance or an operating electric heater This air conditioner has been fully charged with refrigerant at the factory Should a recharg...

Страница 5: ...he allowable maximum charge in a room in kg M is the refrigerant charge amount in the appliance in kg Amin is the required minimum room area in m2 A is the room area in m2 LFL is the lower flammable l...

Страница 6: ...The air inlets and outlets of both indoor and outdoor units should not be surrounded by obstacles or close to any hear source or combustible and or explosive environment The indoor unit inlet and outl...

Страница 7: ...refrigerant concentration detector which can realise two level audible and visual alarm its error must be not more than 10 C The concentration detectors should be calibrated regularly D It is necessa...

Страница 8: ...and an electrical connecting cable The indoor unit is installed on a wall of the room to be air conditioned it must not be installed in a laundry or similar room with high humidity levels The outdoor...

Страница 9: ...tions in this manual may vary slightly from the product purchased All images in this manual are for reference purposes only Parts are not necessarily pictured to scale Product Overview Cont Fig 2 Outd...

Страница 10: ...ont Other inclusions not pictured Remote control holder for wall mounting AAA Batteries x2 Instruction manual Installation manual Warranty certificate Installation hardware 11 Power cable 12 Copper nu...

Страница 11: ...le Install the unit where it is easy to drain any condensation water Observe the minimum clearances around the unit as stated Fig 4 Check the machine operation regularly and leave the necessary spaces...

Страница 12: ...llation diagram Fig 6 Only persons and or companies qualified and experienced in the installation service and repair of refrigerant products should be permitted to do so The purchaser must ensure that...

Страница 13: ...y Drill 32mm deep holes in the wall to fix the plate Use a drill bit to fit the 6mm plugs supplied Insert the plastic anchors into the hole Fix the mounting plate by using the provided tapping screws...

Страница 14: ...ection must be ensured The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage catego...

Страница 15: ...posite directions Fig 12 For R32 refrigerant mechanical connectors should be outdoors Water drainage from the indoor unit The condensed water drainage from the indoor unit is fundamental for the succe...

Страница 16: ...onnection lag the pipe cables and drain pipe with the insulating material Arrange the pipes cables and drain hose well Lag the pipe joints with insulating material securing it with vinyl tape Run the...

Страница 17: ...it for many years to come without loosening The unit must be installed following all relevant local regulations Water drainage from the outdoor unit Condensed water and ice formed in the outdoor unit...

Страница 18: ...ith excessive tightening torque there may also be some leakage as the flange could be damaged The best way to tighten the connections is using a fixed wrench and a torque wrench as illustrated in Fig...

Страница 19: ...y valve by turn and then close it after 10 seconds Check all the joints for leaks using liquid soap or an electronic leak device Turn the body of the 2 way and 3 way valves Disconnect the vacuum pump...

Страница 20: ...water can enter Indoor unit test Does the ON OFF switch work properly Do the HEATING COOLING and FAN modes operate normally Do the TIMER ON and TIMER OFF functions operate properly Does each indicato...

Страница 21: ...21 After Sales Support 1300 886 649 AUS 0800 836 761 NZ info tempo org Information for the Installer Wiring diagrams Indoor wiring diagram...

Страница 22: ...22 After Sales Support 1300 886 649 AUS 0800 836 761 NZ info tempo org Information for the Installer Cont Outdoor wiring diagram...

Страница 23: ...1 4 Gas pipe diameter 12mm 1 2 Length of pipe with standard charge 5m Type of refrigerant R32 Max distance between indoor and outdoor unit 15m Additional gas charge 25g m Max difference between level...

Страница 24: ...torque for protection caps and flange connection Pipe Diameter Tightening Torque N x m Corresponding Stress using a 20cm wrench Part Tightening Torque N x m 6mm 1 4 15 20 Wrist strength Service port n...

Страница 25: ...10 3A Heating 10 2A Power Input Cooling 1190W Heating 1180W Rated Power Input AS NZS 60335 Cooling 2300W Heating 2250W Room size suitability 30 35m2 Rated Voltage and Frequency 220 240V 50Hz Ingress P...

Страница 26: ...regulations concerning the disposal of such materials At the end of its working life do not throw this appliance out with your household rubbish Electrical and electronic products contain substances t...

Страница 27: ...ill in the details below or in the INSTRUCTION manual so you have them on record should you need to contact the installer in the future Proof of professional installation is also required for warranty...

Страница 28: ...ies with the product Product does not work If you encounter problems with this product or if it fails to perform to your expectations make sure to contact our After Sales Support Centre on 1300 886 64...