ocBridge Plus
1. FEATURES
Wireless sensors’ receiver ocBridge is designated for connecting
compatible Ajax devices to any third party wired central unit (panel)
with a help of NC/NO contacts. Ajax system has two-way connection
with the sensors which enables its functioning in two modes: active
mode and passive mode. When the system is in passive mode, wireless
sensors switch to power-saving mode, which makes it possible to extend
significantly battery life.
The equipment specifications can be changed by manufacturer without
prior notice!
2. SPECIFICATIONS
SPECIFICATION
MEANING
Type
wireless
Uses
indoors
Radio signal power
20 mW
Radio frequency band
868 or 915 MHz, depending on the
country of distribution
Maximum distance between wire-
less sensor and receiver ocBridge 2000 m (open area) (6552 ft)
Maximum number of connected
devices
100
Radio channel jamming detection
available
Sensor’s efficiency control
available
Alerts and events logs
available
External antenna connection
available
Firmware update
available
Tamper protection
available
Number of wireless inputs/outputs 13 (8+4+1)/1
Power supply
USB (only for system setup); (digital
input) +/ground
Power supply voltage
DC 8 – 14 V; USB 5 В (only for system
setup)
Operation temperatures range
from -20°С (-20°F) to +50°С (+122°F)
Operation humidity
up to 90%
Dimensions
95 x 92 x 18 mm (3,74 x 3,62 x 0,71 in)
(with antennas)
3. COMPONENTS
Wireless sensors’ receiver, battery СR2032, manual, instalation CD.
INDICATION
DESCRIPTION
Green light is permanent, red
light does not blink
OcBridge is in configuration mode. In con-
figuration, there are Pages “Radio zones”
or «Events memory» are opened. During
this period, the sensors do not receive
the responses to the alarm signals and
statuses.
Green - blinks once per second
(before, the green light was
permanent), and the red -
blinks during 30 seconds
New radio set unit detection mode is on.
The red blinks momentarily
A moment when the ocBridge receiver
register a new device
The green - blinks for 10 min-
utes and the red is permanent;
no red light
Searching for all devices after the previ-
ously saved PC configuration is download-
ed, system is armed; system is disarmed.
No green and red light
The receiver is in in the operating mode,
the system is disarmed
Permanent red light
The receiver is in operating mode, the
system is armed.
Permanent green light, the red
light is blinking very fast
Radio signal is tested in order to connected
sensor or other device.
Green light blinks momentarily New detectors' polling period started, 36
seconds by default.
Red/green- blinks momentarily Failure is detected
ATTENTION!
If the receiver ocBridge is connected to the wire central unit, the digital
input «IN» (wire input) MUST have connection with relay output or
transistor output from the central unit, and this output must be inverted
when the central unit is being armed or disarmed. Detailed description
of connection to the central unit described in paragraph 6.5.
1 – ocBridge main board
2 – terminal strip for
connection to the
main zones of the
central unit
3 – 8 red lights
indicators of the
main zones
4 – mini USB connector
5 – red and green light
indicators (consult
the table for the
description)
6 – «opening» tamper
button
7 – green power supply
indicator
8 – battery for backup
saving
9 – IN digital input
10 – power supply
switch
PICTURE 1. ocBridge wireless sensors receiver
PICTURE 2. Selecting the COM port for connecting the
receiver to the computer
11 – terminal strip for connection to the central unit service zones
12 – 4 green indicators of the service zones
13 – «breakdown» tamper button (on the reverse of the main board)
14 – antennas
4. SENSORS’ HANDLING
4.1. Connect the ocBridge to the computer with a help of USB cable (type
А–miniUSB) through connector «4» (PICTURE 1). Turn on the receiver
with the switch «10» (PICTURE 1).
If it is the first connection, wait until the system identify new device and
install the software drivers. If the drivers were not installed automatically,
you will have to install the driver-program vcpdriver_v1.3.1 manually.
There are different versions of this program for x86 and x64 Windows
platforms. You can find two files: VCP_V1.3.1_Setup.exe for 32-bit
Windows operating systems and VCP_V1.3.1_Setup_x64.exe – for 64-bit
Windows operating systems on the CD. If the wrong driver was installed, at
first, it is necessary to uninstall it (through Windows programs uninstall),
then reboot the computer and install the necessary software driver. Also,
NET Framework 4 (or newer version) should be installed. After drivers
instalation, launch the program «Ajax ocBridge configurator». Paragraph
5 of this manual provides the details about the program «Ajax ocBridge
configurator» functioning.
In the program settings in «Ajax ocBridge configurator» settings (menu
«Connection» - «Setting»), select COM port that is chosen by the system
for the receiver (PICTURE 2), click «OK» and then the «Connect» button.
«Ajax ocBridge configurator» is ready to work with the ocBridge receiver.
Light «5» (PICTURE 1) indication description:
1 2
4
6
5
8
7
10
9
11
13
14
4.2. All devices that you want to connect to the ocBridge must be registered
with a help of «Ajax ocBridge configurator». In order to register the
sensors, it is necessary to create radio zones in the configurator in case
of it had not been done before. To do this select the “Radio zone” and click
«Add zone» button (PICTURE 3).
3
12