background image

LED Brightness

Displays current brightness level of indicator light:

Protection against accidental activation

Displays the selected type of protection against
accidental activation:

Routed Through ReX

Display the status of using the ReX range
extender

Temporary Deactivation

Displays the status of the device: active or
completely disabled by the user

Firmware

Button firmware version

ID

Device ID

Configuration

You can adjust the device parameters in the settings section:

Parameter

Value

First field

Name of the device, can be changed

Room

The choice of the virtual room that the device is

Mute Fire Alarm

Disabled (no display)

Low

Max

Off — protection disabled.

Long press — in order to send alarm you
should hold the button down for more than 1.5
seconds.

Double-pressing — in order to send alarm you
should double-press on the button with a
pause of no more than 0.5 seconds.

1. Ajax app 

 Devices 

 

 Button 

 Settings 

Содержание Button

Страница 1: ...compatible with only No support for and integration modules Button is connected to the security system and configured via on iOS Android macOS and Windows The users are alerted of all alarms and events via push notifications SMS and phone calls if enabled Functional elements automation devices Ajax hubs ocBridge Plus uartBridge Ajax apps Buy panic button Button ...

Страница 2: ...n and signal about a threat or inform about an intrusion as well as a fire gas or medical alarm You can choose the type of alarm in the button settings The text of alarm notifications depends on the selected type as well as the event codes transmitted to the central monitoring station of the security company CMS You can bind the action of an automation device or to a button press in the Button Scena...

Страница 3: ...hub You can assign Button to another hub or ReX manually in the app Connecting the button to the Ajax security system Prior to initiating connection Only users with administrative rights can add a device to the hub In order to connect a Button ReX 1 Follow the hub instructions to install the Create an account add a hub to the app and create at least one room Ajax application 2 Enter the Ajax app 3...

Страница 4: ...ng commands to the old hub Note that after being added to the new hub the Button is not automatically removed from the device list of the old hub This must be done manually through the Ajax application States Button statuses can be viewed in the device menu Parameter Value Battery Charge Battery level of the device Two states available Operating mode Displays the operating mode of the button Three...

Страница 5: ...r Firmware Button firmware version ID Device ID Configuration You can adjust the device parameters in the settings section Parameter Value First field Name of the device can be changed Room The choice of the virtual room that the device is Mute Fire Alarm Disabled no display Low Max Off protection disabled Long press in order to send alarm you should hold the button down for more than 1 5 seconds Dou...

Страница 6: ...tor lights Accidental press protection available only in panic mode Displays the selected type of protection against accidental activation Panic sends an alarm when pressed Control controls automation devices by short or long 2 sec pressing Mute Fire Alarm when pressed mutes the fire alarm of FireProtect FireProtect Plus detectors Learn more Intrusion Fire Medical Panic button Gas Disabled no displ...

Страница 7: ... Operating indication Button status is indicated with red or green LED indicators Category Indication Event Linking to security system Green LEDs flash 6 times The button is not registered in any security system Lights up green for a few seconds Adding a button to the security system Command delivery indication Lights up green briefly Command is delivered to security system Lights up red briefly Comm...

Страница 8: ...s a panic button the Button is used to call for security company or help as well as for emergency notification through the app or sirens Button support 5 types of alarms intrusion fire medical gas leak and panic button You can choose the type of alarm in the device settings The text of alarm notifications depends on the selected type as well as the event codes transmitted to the central monitoring st...

Страница 9: ... the button is pressed for more than 3 seconds These pressings can trigger the execution of an action by one or more automation devices Relay WallSwitch or Socket To bind an automation device action to a long or short press of a Button 1 Open the and go to the Devices tab Ajax app 2 Select Button in the list of devices and go to settings by clicking the gear icon 3 Select the Control mode in the B...

Страница 10: ...click Create scenario if you are creating a scenario for the first time or Add scenario if scenarios have already been created in the security system Select a pressing option to run the scenario Short press or Long press 7 Select the automation device to execute the action ...

Страница 11: ...ter the Scenario Name and specify the Device Action to be executed by pressing the Button When configuring a scenario for Relay which is in pulse mode the Device Action Switch on Switch off Switch the state ...

Страница 12: ...e and pulse duration are set in the Relay settings 9 Click Save The scenario will appear in the list of device scenarios Interconnected FireProtect Alarms are disabled pressing the Button mutes the sirens of triggered FireProtect FireProtect Plus detectors The Interconnected FireProtect Alarms have already propagated by the first press of the Button all fire detectors sirens are muted except for tho...

Страница 13: ...e When cleaning the key fob body use cleaners that are suitable for technical maintenance Never use substances containing alcohol acetone gasoline and other active solvents to clean the Button 2 Press the button to test whether the commands can reach the hub If not choose another location or use a When connecting Button via ReX keep in mind that the button does not automatically switch between ran...

Страница 14: ...tion in the Ajax app and the LED will steadily light up red and go out each time the button is pressed Technical Specifications Number of buttons 1 LED backlight indicating command delivery Available Protection against accidental activation Available in panic mode Frequency band 868 0 868 6 MHz or 868 7 869 2 MHz depending on the sales region Compatibility Operates with all Ajax and featuring OS Ma...

Страница 15: ...d liability company is valid for 2 years after purchase and does not extend to the bundled battery If the device does not function properly we recommend that you first contact the support service as technical issues can be resolved remotely in half of the cases Technical support 1 Button 2 Pre installed CR2032 battery 3 Double sided tape 4 Quick Start Guide Warranty obligations User agreement suppo...