![AJAX Systems Hub Plus Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/ajax-systems/hub-plus/hub-plus_user-manual_2883554036.webp)
/
Primary IP address
Secondary IP address
Alarm sending channels
In this menu, channels for sending alarms and events to the central monitoring station of
the security company are selected. Hub Plus can send alarms and events to the central
monitoring station via Ethernet, UMTS, and Wi-Fi. We recommend that you use all
communication channels at once — this will increase the transmission reliability and secure
against failures on the telecom operators’ side.
Protocol — the choice of the protocol used by the hub to send alarms to the central
monitoring station of the security company via a direct connection. Available protocols:
Ajax Translator (Contact-ID) and SIA.
Connect on demand. Enable this option if you need to connect to the CMS (Central
Monitoring Station) only when transmitting an event. If the option is disabled, the
connection is maintained continuously. The option is available only for the SIA protocol.
Object number — the number of an object in the monitoring station (hub).
IP address and Port are settings of the primary IP address and port of the security
company server to which events and alarms are sent.
IP address and Port are settings of the secondary IP address and port of the security
company server to which events and alarms are sent.
Ethernet — enables event and alarm transmission via Ethernet.