Jumper J2 Settings

 

Jumper J2 is located at the bottom of the card (shown in the photo below). The 
meaning of the jumper settings is detailled in the illustration:

 

Installation 

 

Typically, RH10MD installation consists of the following:

 

1.

 

disconnect power from the frame (remove line cord)

 

2.

 

remove the FR1/FR2 front panel

 

3.

 

install RH10MD card module

 

4.

 

replace the FR1/FR2 front panel

 

5.

 

apply power to the frame by connecting a north american-style power cord from 
the frame to mains power (90 to 260 VAC)

 

!

 

Warning!

 

Ensure Mains Power is disconnected before installing the FR1 or FR2 frame R-series 
modules into the frame, or installing and removing options. If a Mains switch is not 
provided, the power cord(s) of this equipment provide the means of disconnection. 
The socket outlet must be installed near the equipment and must be easily 

accessible.

 

Warning!

 

FR2 Dual Power Cord Notice—please read this. To reduce the risk of electrical shock, 
disconnect both power cords before servicing equipment.

 

Caution! 

 

The FR1/FR2 front fan door is heavy and is not hinged. Remove with Caution.

 

Instructions for removing the frame front door for module installation is discussed in 
the 

 

FR1/FR2 User Manual.

1
2
3

6
5
4

Jumper

J2

Jumper Between Pins 1 and 2:   
  ON = RP215 is used to synchronize 3:2 pulldown sequence 
  OFF = RP1

88

 is used. 

In both cases the “A Frame” is synchronized to frame with timecode “xx:00”

Jumper Between Pins 5 and 6:
  ON = Output start of vertical blanking lines up with input start of vertical blanking
  OFF = Output start of vertical sync lines up with input start of vertical sync (per RP16

8

)

 

Содержание RH10MD

Страница 1: ...www aja com Installation and Operation Guide B e c a u s e i t m a t t e r s RH10MD HD Downconverter and Re clocking Distribution Amplifier dual rate R series Card Module Published 6 30 10...

Страница 2: ...iod and make suitable arrangements for the performance of service The Customer shall be responsible for packaging and shipping the defective product to a designated service center nominated by AJA Vid...

Страница 3: ...ther 4 3 or 16 9 monitors When used with 4 3 monitors both Letterbox and Crop modes are supported The RH10MD is dual rate HD SD and supports SDI inputs Four channel AES embedded audio is passed throug...

Страница 4: ...ent or Composite ReClock Cable EQ SD Out 2 SD Out 1 SD Out 3 SD Out 4 Set by Switches Y G Composite Composite Pb B Y Composite Pr R C Composite Cable Drivers D A Conversion H V Filtering and Decimatio...

Страница 5: ...o the large backplane connector where the card plugs into an FR1 FR2 chassis These jumpers are labeled as 1 2 3 or 4 corresponding to the four SD output BNCs This arrangement supports any combination...

Страница 6: ...Pr DOWN RGB 3 Pedestal UP Pedestal Off DOWN Pedestal On 4 Crop UP Horizontal Edges cropped off from input lines all output lines are used DOWN Black Bars top and bottom all of input line is visible ho...

Страница 7: ...witch is not provided the power cord s of this equipment provide the means of disconnection The socket outlet must be installed near the equipment and must be easily accessible Warning FR2 Dual Power...

Страница 8: ...9 94 60 Hz Frame Rates 23 98 525 59 94 3 2 pulldown 24 525 59 94 3 2 pulldown drop frame 25 625 50 50 625 50 59 94 525 59 94 60 525 59 94 drop frame Delay 1 frame audio and video Outputs SDI SMPTE 259...

Страница 9: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interferen...

Страница 10: ...0004 6 2007 EN61000 4 11 2004 The product is also licensed for additional country specific standards as required for the International Marketplace Warning This is a Class A product In a domestic envir...

Страница 11: ...manual Before operating your unit please read the instructions in this document Warning Read and follow all warning notices and instructions marked on the product or included in the documentation Aver...

Страница 12: ...allare in conformit con le istruzioni del fornitore Warning Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Avert...

Страница 13: ...rovesciato del liquido stato rovesciato o qualche oggetto caduto nel dispositivo il dispositivo stato esposto a pioggia o umidit non funziona correttamente o caduto Caution This device is a Class A pr...

Страница 14: ...l los cable s el ctrico s del equipo La toma de corriente debe ser instalada cerca del equipo y debe estar f cilmente accesible Advert ncia Certifique se de que a alimenta o principal esteja desconect...

Страница 15: ...vec pr caution Achtung Die vordere Gebl set r des FR1 FR2 ist schwer und l sst sich nicht klappen Bitte vorsichtig entfernen Precauci n La puerta del ventilador delantero del FR1 FR2 es pesada y no po...

Страница 16: ...16...

Отзывы: