18

Drive Operation and Maintenance

To back up any available files or volumes,

 click on the Backup button.

To restore any available files or volumes,

 click on the Restore button.

To duplicate any available volume to any other available volume,

 click on the

Duplicate button.

To execute a script,

 click on the Run button.

To view the Help, follow the following procedure.

(1) Double click on the Retrospect Help icon as shown in the previous page, or

click “Help” on the Menu Bar. Then select the Retrospect Help.

(2) Click on the Topics button.

To read the Retrospect User’s Guide.PDF.

You need Acrobat Reader to read the Retrospect User’s Guide.PDF.
The Acrobat Reader is contained in the Install Retrospect folder in the backup
software CD-ROM. Install the Acrobat Reader to your Mac, if you don’t have it.
Then double click on the Retrospect User’s Guide.PDF.

From this point on, follow the directions given by the backup software.

Technical Support regarding the Backup Software

See the last page.

Note

• The default software data compression is off.

When you need a large backup capacity more than 4 GB, you have to work the
software data compression.
To work the software data compression, refer to the Retrospect User’s Guide.PDF
or troubleshooting “An 8 GB backup is not possible on a TR-4” (next page).

• AIWA recommends to compare and verify each backed up file with the original file

after performing a backup, to ensure the reliability of the each backed up file.
To compare and verify them automatically, check the check mark in the
“Verification” check box on Backup Options before starting the backup operation.

Содержание TD-UM8000

Страница 1: ...hen you contact your AIWA dealer in case of difficulty Model No Serial No TD U8000 Hardware Installation Manual To Call Technical Support 800 920 2673 8 00AM to 5 00PM pacific time Monday through Frid...

Страница 2: ...2...

Страница 3: ...4 Inserting and Removing Tapes 14 Cleaning the Read Write Head 16 Cleaning the Cabinet 16 Starting the Backup Software 17 Troubleshooting 19 Appendix 20 Technical Support 21 Specifications 22 EMI EMC...

Страница 4: ...fitted with a cooling fan to prevent the internal temperature becoming excessive Ensure that the unit is operated at a suitable spacing from walls and other obstructions so that there is a clear passa...

Страница 5: ...e cartridge is first loaded into a drive b the cartridge is exposed to temperature changes of 16 C or more or c one section of tape has been used excessively in a single operating period Operating con...

Страница 6: ...a Hard Disk Drive Operating System OS Requirements This unit works with the following operating system Mac OS 8 1 or later Note If you are using an iMac with Mac OS 8 1 download iMac Update 1 0 softwa...

Страница 7: ...ged in even while the computer is powered on hot plug Using a USB hub as many as 127 peripherals can be plugged into a single computer Note Regarding the use of this unit with a USB When this unit is...

Страница 8: ...computer make sure that the package contains the following items Note Remember to keep all packing materials for later use especially the polystyrene foam cushioning and the antistatic bag which cont...

Страница 9: ...9 Names and Function of Parts Front panel Rear panel STATUS indicator ACCESS indicator POWER indicator Tape cartridge slot USB connector TO COMPUTER Cooling fan underneath Power switch AC power cord...

Страница 10: ...click on the Install Retrospect folder 4 Double click on the Install Retrospect installer icon 5 The welcome to the Retrospect Installer window appears Click on the Continue button 6 The Dantz Softwar...

Страница 11: ...driver for this unit will be installed into the Extensions folder in the System folder Setting the Tape Drive You can set this unit either horizontally or vertically Set the unit on a flat place Do no...

Страница 12: ...s the connection This unit can be used with your Mac To verify whether this unit is recognized or not see the Appendix page 20 MEMO The best performance can be ensured by connecting this unit directly...

Страница 13: ...the USB cable 4 Press the power switch to turn off this unit 5 Disconnect the AC power cord of this unit from an AC outlet Caution Do not attempt to disconnect this unit during the tape backup operati...

Страница 14: ...cked position Inserting and Removing Tapes Hold the tape cartridge and insert it as illustrated below Push the cartridge in until it locks into place with a click When the cartridge is loaded the ACCE...

Страница 15: ...show the state of the unit as shown below Note If the STATUS indicator blinks in amber remove the cartridge from the unit then re insert it If the indicator still blinks in amber use a new tape cartr...

Страница 16: ...TRAVAN NS Head Cleaning Cartridge Never use other head cleaning cartridges or cleaning kits Do not clean the head by using a cotton swab moistened with an alcohol Before cleaning the read write head...

Страница 17: ...the online Help or Retrospect User s Guide PDF 1 Insert a tape cartridge into the tape cartridge slot 2 Double click on the Retrospect folder in the Macintosh HD The following window will appear 3 Dou...

Страница 18: ...der in the backup software CD ROM Install the Acrobat Reader to your Mac if you don t have it Then double click on the Retrospect User s Guide PDF From this point on follow the directions given by the...

Страница 19: ...TR 4 is 4 GB The figure of 8 GB assumes software data compression at a ratio of 2 1 The compression ratio depends on the data concerned so a capacity of 8 GB may not always be attainable b The sofwar...

Страница 20: ...ndow will appear 3 Select the Media Handling in the list of preferences category 4 Check the Retension Tapes check box d This unit may stop frequently due to the length of time taken for software data...

Страница 21: ...both it and a telephone are easily accessible f Call AIWA Technical Support at the hours and numbers listed on the cover of this manual The technical support staff will ask several questions regardin...

Страница 22: ...otice Specifications Declaration of Conformity Company name AIWA DIGITAL TECHNOLOGY INC Address 1932 E Deere Avenue Suite 230 Santa Ana CA 92705 Telephone Number 949 252 1800 Type of Product Data Stre...

Страница 23: ...changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Caution Shielded I O cables must be used when operating this equipment A s...

Страница 24: ...up Software Dantz Development Corporation 4 Orinda Way Building C Orinda CA 94563 USA Standard Technical Support Phone 925 253 3050 World Wide Web www dantz com Monday Thursday 9 00 AM to 4 00 PM Paci...

Отзывы: