-34-
ADJUSTMENT
Test Equipment
• Oscilloscope
• Test Tape
• AC Millivolt Meter
TTV-P1
P3D02
IC301
PMC01
MS501
IC5F1
IC501
PMK01
T101
H/SW
P3D01
TU701
W5D2
W5D3
MAIN C.B (TOP VIEW)
Adjustment Location
1. Servo Adjustment
1) PG Adjustment
MODE
MEASUREMENT POINT
ADJUSTMENT POINT
SPECIFICATION
PLAY
VIDEO OUT
'PLAY' KEY (SET)
6.5H
±
0.5H
(TTV-P1)
H/SW (W5D2, W5D3)
'O' KEY (REMOCON)
• Adjustment Procedure
1. Insert the PAL SP Test Tape (TTV-P1) and play.
Note - Adjust the distance of X, pressing the Tr) or Tracking(-) when the “ATR” is blink after the
PAL SP Test Tape is inserted.
2. Connect the CH1 of the oscilloscope to the H/SW (W5D2, W5D3) and CH2 to the Video Out for the VCR.
3. Trigger the mixed Video Signal of CH2 to the CH1 H.SW (W5D2, W5D3), and then check the distance (time
difference), which is from the selected A(B) Head point of the H.SW(W5D2, W5D3) signal to the starting
point of the vertical synchronized signal, to 6.5H
±
0.5H (416
µ
s, 1H=64.0
µ
s).
• WAVEFORM
H/SW
6.5H(616 s)
Composite
VIDEO