– 12 –
MD Electrical Adjustment
Perform all MD block adjustments and checking in test mode.
When “NO ADJUST” appears on the display, perform all the adjustments.
Measuring Device and Tools
Attached Remote Controller
Temperature indicator (Degree Celsius), Laser Power meter (available to measure up to 10mW)
Test DISC: TGYS-1 or TDYS-1 (or soft disc), MDW-74 (or similar product)
Before Adjustment
Use a DISC that is not scratched or contaminated for the adjustment.
(The adjustment may not be able to be performed if the DISC is scratched or contaminated.)
During adjustment, do not reverse the MD mechanism or place it in a slanting position.
Adjustment Procedure
All the adjustment procedures are listed in the flow chart below.
Follow 1 to 7 of the flow chart for the adjustment procedure.
Adjustment Procedure
START
1
Activate TEST MODE
2
EEPROM Initialisation
3
Temperature Compensation
Adjustment
4
Laser Power Check
5
AUTO SEQUENCE ADJ
6
Error Rate Check
7
After Adjustment Check
END
About the mark in the procedure
Show button operation.
ELECTRICAL ADJUSTMENT