TOT706
22
PAR06 = 0
press
key “SET” +
key “
▲
”
to go to the
programming
of parameters
PAR06 = 1
PAR06 = 2
PAR06 = 3
press
key “SET” +
key “
▲
”
to go
to programming
access code
“3409”
To access parameters programming or point setting use the buttons on the fron-
tal panel according to the level of keyboard protection programmed in the PAR06.
How to reset (default).
Reseting (default) is necessary when the appliance device presents anomalies or
because the technician wants to reset the indicator beginning from the initial data of
factory.
Procedure:
•
Switch off the indicator.
•
Press and hold the keys “
▲
” + “
►
”.
•
Switch on the indicator.
•
The message “dEFt” will be displayed.
•
Release the keys.
•
The indicator will get back to the normal operation with the data of factory.
•
Programme the parameters accordino your needs.
DEFAULT
KEYBOARD PROTECTION CODES