INSTALLATION
The Airzone-Lutron interface operates as an interpreter using the services defined by the Lutron HomeWorks QS Processor to
connect Lutron and Airzone systems via Ethernet using the Lutron integration protocol.
Note
: The HomeWorks QS Processor and the Palladiom thermostat must use software version 13.0 or newer.
The Airzone-Lutron interface is a Plug&Play device which, when connected to the Airzone Main Control Board and to the
HomeWorks QS Processor via Ethernet using the Lutron integration protocol, configures itself and configures the Main Board
to work with the Lutron system.
Important
: It is necessary to have at least one Airzone Blueface thermostat connected all the time.
INSTALLATION ON THE MAIN BOARD
The Airzone-Lutron interface connects to the Airzone Main Control Board using the automation bus.
The ethernet cable should be connected to the Airzone-Lutron interface. Once the control board has the interface connected,
it will auto-detect the presence of the interface and will automatically set the parameters to enable the operation with the
Lutron system.
SYSTEM IDENTIFICATION
To start the configuration process, it is necessary to identify the system, to do this, remove the Blueface thermostat from its
base and check the code printed on the label located on the back of the thermostat.
Depending on the code printed on the label the system will be configured in different ways, for further information, please
refer to the documentation related to each system:
Identification
Related documentation
AZCE6
Flexa 3.0 / Innobus Pro6 System
AZDI6
Acuazone / Innobus Pro32 System
AZRA6
RadianT365 System
AZVAF
VAF System
AZZBS
ZBS System
AZZS6
2 pipes / 2 wires System
Quick Guide
Installation Manual