Airxcel Coleman-Mach 4735 Series Скачать руководство пользователя страница 5

  

 

Position the end louvers to the desired amount of discharge air flow. 
 
Discharge air temperature can be controlled to some extent by opening or closing the louvers.  When the 
louvers are closed, the warmest localized discharge air is achieved.  Fully opened louvers will throw the warm 
discharge air to the back and front of the vehicle for more efficient circulation and faster warm-up.  

Although 

the air temperature is lower with the louvers fully opened, the heating capacity is still the same. 
 

If dirty filters or overly restricted louver position results in a cessation of electric heat, turn off power to the unit 
at the mode selector switch.  Wait ten minutes and restore power.  The heater is equipped with a safety lock-out 
switch.  Correct the low air event to insure proper operation. 

 
V. 

For Air Circulation Only (Refer to Figure 1, page 3). 

 

A. 

Turn the selector switch to “LOW FAN” or for maximum air flow, to “HIGH FAN”. 

 
B. 

Position the louvers to the desired direction the discharge air is to flow. 

 

NOTE 

 

 

 

 

 

When the selector switch is in the “LOW FAN” or 

 

 

 

 

“HIGH FAN” position, the blower motor will 

 

 

 

 

operate continuously. 

 

V.  ROUTINE MAINTENANCE 

 

I. 

Owner 

 

One of the biggest advantages to your new Coleman-Mach air conditioner is that the maintenance needed to 
keep the unit in good care is minimal.  In fact about the only thing you, the owner, must take care of is the 
cleaning and replacement of the filters.   
 
Filters are made from long life non-allergenic natural fibers or foam which can be cleaned and reused, and 
which completely filter the circulated air when the air conditioner is in operation.  If the filters are not cleaned 
at regular intervals, they may become partially clogged with lint, dirt, grease, etc.  A clogged filter will produce 
a loss of air volume and may eventually cause an icing-up of the cooling (evaporator coil). 
 

IMPORTANT 

 

Do not operate your air conditioner for extended periods of time without the filter installed. 

 

An even more serious condition occurs when the air conditioner is operated without a filter.  
When this happens the lint, grease, etc. that are normally stopped by the filter are now 
accumulating in the cooling coil.  This not only leads to a loss of air volume and a possible  
icing-up of the cooling coil, but could also result in serious damage to the operating  
components of the air conditioner. 

 

We recommend that the filters be cleaned or changed at least every two weeks when the air 
conditioner is in operation. 

-5- 

“More information https://www.caravansplus.com.au"

Содержание Coleman-Mach 4735 Series

Страница 1: ...IR CONDITIONER Service Contact Coast to Coast RV Services Pty Ltd PO BOX 415 REGENTS PARK DC NSW 2143 Australia Tel 61 2 9645 7600 technical coastrv com au Coleman is a registered trademark of The Coleman Company Inc used under license Mach is a registered trademark More information https www caravansplus com au ...

Страница 2: ...umber of the unit Both numbers can be found on the data label on the unit Model No ________________________ Serial No ________________________ II OPERATING GUIDELINES The air conditioner is designed to provide cooling and dehumidification An electric coil provides heating in cool weather Note The electric heating assembly is intended to take the chill out of the indoor air when the air is a few de...

Страница 3: ...ons 9400 ceiling assemblies will have the knobs at the bottom of the ceiling assembly See Figure 2 The Operation section explains the operational characteristics of each mode of operation B The Thermostat temperature control In the cooling mode the thermostat regulates the ON and OFF temperature setting at which the compressor will operate The thermostat also controls the ON and OFF temperature se...

Страница 4: ...efrost before normal cooling operation is resumed During this time operate the unit in the HIGH FAN position with the system at maximum air flow When increased or full air flow is observed the cooling coil should be clear of ice III Short Cycling When an air conditioner is in operation its compressor circulates refrigerant under high pressure Once off it will take two to three minutes for this hig...

Страница 5: ...of the biggest advantages to your new Coleman Mach air conditioner is that the maintenance needed to keep the unit in good care is minimal In fact about the only thing you the owner must take care of is the cleaning and replacement of the filters Filters are made from long life non allergenic natural fibers or foam which can be cleaned and reused and which completely filter the circulated air when...

Страница 6: ...s to trip the circuit breakers have an electrician check the starting amperage and running amperage on the unit If the circuit breakers continue to trip and the electrical consumption is found to be normal it will require the replacement of the faulty circuit breaker If all electrical power to the air conditioner is normal but neither the fan nor the compressor will operate the connector plug loca...

Страница 7: ...ess the filters pull on the tabs on the return air grilles The filters should be washed in warm water or vacuumed clean and replaced The filters should be inspected every 2 weeks and cleaned as required Note If the unit is operated in a dusty environment the filters should be inspected and cleaned more frequently FIGURE 2 7 Tabs to access filter Tabs to access filter More information https www car...

Страница 8: ...me type rather than being repaired Refurbished parts may be used to repair the goods 3 WHAT THE CLIENT MUST DO TO CLAIM THE WARRANTY 3 1 To claim the benefit of the warranty the Client will need to sequentially i first contact the Supplier and ii present the defective Goods to the Supplier for inspection including inspection for defective workmanship or otherwise provide evidence of the claimed De...

Страница 9: ...hould be referred to the installer The Goods must be installed in accordance with the Manufacturer s instructions and any relevant legislation or code 6 3 This warranty covers the Client only and it is not transferrable if the Goods are sold by the Client during the warranty period 7 WARRANTY EXCLUSIONS 7 1 This warranty will not apply where i the Goods have been improperly modified or repaired or...

Страница 10: ...ox Yes No Receipt No Description of defects Give as much detail as possible Use a separate page if required Date of purchase services provided I hereby declare that the information provided above is true and correct and to the best of my knowledge and belief and I have complied with all the conditions of the warranty Signed Name please print Dated Please note the issue or completion of this form b...

Страница 11: ...RV Products Division Airxcel Inc RV Products Division P O Box 4020 Wichita KS 67204 1976 671 Rev 1 3 15 PP More information https www caravansplus com au ...

Отзывы: