10A. PRINTED CIRCUIT BOARD
-16-
L2
L1
Evaporator Freeze
Thermistor Connections
Open At 22 ±3
Close At 65 ±3
Indoor Blower
High Speed
Power
Indoor Blower Low Speed Power
W1 = 1
st
Stage Heat Signal From Thermostat
W2 = 2
nd
Stage Heat Signal From Thermostat
GH = Indoor Blower Signal From Thermostat
Y = Compressor Signal From Thermostat
Power To
Compressor
Power To 2
nd
Stage Heat
Fuse
Power To Outdoor Fan
Power To 1
st
Stage Heat
Output Signal To Start
Generator
12V-
12V+
Low Pressure Switch Connections
Open At 10 ±5 PSI, Close At 40 ±5 PSI