TROUBLESHOOTING
Service Manual
– YBZE DCI 1-A.1 GB
13-3
2. Compressor wiring mistake.
3. Liquid and gas valve are not open.
4. EEV damaged or not proper working
5. Poor heat exchange.
6. Over charged system.
PFC protection
HC
6
1. PFC module assembly problem.
2. Poor heat exchange of Heatsink
3. PFC reactor problem.
4. Abnormal power voltage
5. PFC circuit problem on PCB
Desynchronizing of compressor
H7
7
1. Abnormal power input voltage.
2. Compressor wiring mistake.
3. Liquid and gas valve are not open.
4. EEV damaged or not proper working
5. Poor heat exchange.
6. Over charged system.
。
Compressor start-up failure
Lc
11
1. Compressor wiring mistake
2. Over charged system
3. System not balanced before compressor
starting
4. Compressor problem
Compressor
phase
current
detection problem
U1
12
Phase
current
detection
circuit
for
compressor has problem.
DC over current
P5
15
1. Abnormal power input voltage.
2. Compressor wiring mistake.
3. Liquid and gas valve are not open.
4. EEV damaged or not proper working
5. Poor heat exchange.
6. Over charged system.
Charging
malfunction
of
capacitor
PU
17
1. Reactor open
2. Charging relay or other components
damaged on PCB.
HST failure
P7
18
1. Senor was broken or damaged
2. PCB temperature detection circuit has
problem
HST over heating protection
P8
19
1. Insufficient attachment of IPM module to
Heatsink
2. Outdoor PCB problem.
DC under voltage
PL
21
1. AC input voltage is too low
2. Reactor has problem
3. ODU PCB has problem
Lack
Phase
Protection
of
Compressor
Ld
1. Compressor wiring problem
2. Compressor problem
3. IPM module problem or compressor
current detection circuit has problem
4. Compressor malfunction due to EEV
problem
Demagnetic
protection
of
compressor
HE
DC compressor has problem
Malfunction of voltage dropping
for DC BUS
U3
20
Supply voltage is unstable
Outdoor EEPROM Malfunction
EE
Outdoor PCB problem
Installation test failed
dn
1. Check the communication wires
2. Check the EEV
AC Current detection problem
U5
13
Outdoor main board damaged
Outdoor
DC
fan
motor
malfunction
L3
23
1.DC fan motor malfunction or blocked
2.Bad connection
Under installation test
dd
normal status
Refrigerant Recovery
Fo
normal status
Dry mode
AL
normal status
Outdoor Deicing or Oil Return
H1
normal status
The RV is abnormal
U7
20
1.Supply voltage is lower than AC175V;
2.Wiring terminal RV is loosened or broken;
3.RV is damaged.
Downloaded from
www.Manualslib.com
manuals search engine
Содержание YBZE218-324-430
Страница 4: ...Downloaded from www Manualslib com manuals search engine...
Страница 14: ...Downloaded from www Manualslib com manuals search engine...
Страница 16: ...Downloaded from www Manualslib com manuals search engine...
Страница 20: ...Downloaded from www Manualslib com manuals search engine...
Страница 22: ...Downloaded from www Manualslib com manuals search engine...
Страница 24: ...Downloaded from www Manualslib com manuals search engine...
Страница 26: ...Downloaded from www Manualslib com manuals search engine...
Страница 32: ...Downloaded from www Manualslib com manuals search engine...
Страница 34: ...Downloaded from www Manualslib com manuals search engine...
Страница 36: ...Downloaded from www Manualslib com manuals search engine...
Страница 50: ...Downloaded from www Manualslib com manuals search engine...