Using the Wireless Remote Control Unit

Slide switch

This is used to set the operation mode of the indoor units and to set the flaps.

Depending on the indoor unit used, the operation display and airflow 
direction display settings will differ as shown below.

Use a pointed implement to change the switch position.

When the switch position has been changed, press the ACL button.

*   For details on the flap functions, refer to the operating instructions of the 

indoor unit used.

Before use, check that the slide switch has been set to the position shown 
in the figure above.  For details on how to set the slide switch, consult your 
dealer.

How to install batteries

1.

Slide the cover in the direction indicated by 
the arrow and remove it.

2.

Install two AAA alkaline batteries. Make 
sure the batteries point in the direction 
marked in the battery compartment.

3.

Use a pointed implement to press the ACL 
button.

The batteries last about a year, depending 
on how much you use the wireless remote 
control unit. Replace the batteries when the 
wireless remote control unit’s display fails to 
light, or when the remote control cannot be 
used to change the air conditioner’s 
settings.

When the batteries are to be replaced, make sure that both batteries are 
new and that the same kind of battery is used.

Remove the batteries if the wireless remote control unit is not going to be 
used for a prolonged period.

Dispose of the used batteries at the designated location.

Model which supports 

different flap settings

Swing-only model

No-flap model

Slide switch position

Flap display on wireless 
remote control unit

With the battery cover 
removed

Heat pump (with auto 

cooling/heating 

function)

Heat pump (without 

auto cooling/heating 

function)

Cooling only

Operation mode display 
on wireless remote 
control unit

Slide switch position

ACL 
button

Cover

OI-824-11-EG

01_Airwell_ST-NKFL7R_EN.fm  Page 11  Thursday, June 15, 2006  4:18 PM

Содержание ST-NDHP 24R

Страница 1: ...R ST NWFL 18R ST NWFL 24R Standard Static Pressure ST NDLP 7R ST NDLP 9R ST NDLP 12R ST NDLP 16R ST NDLP 18R ST NDLP 24R ST NDLP 36R ST NDLP 48R High Static Pressure ST NDHP 24R ST NDHP 36R ST NDHP 48...

Страница 2: ...Date of purchase ________________________________________________ Dealer s address ________________________________________________ Phone number ________________ DECLARATION OF CONFORMITY This product...

Страница 3: ...r where excessively high heat generating objects are placed Avoid To protect the air conditioner from heavy corrosion avoid installing the outdoor unit where salty sea water can splash directly onto i...

Страница 4: ...nal Air outlet Ceiling panel optional Air intake grille air intake CONCEALED DUCT NDLP type standard static pressure Water drain Flexible duct optional Canvas duct optional Air intake grille air intak...

Страница 5: ...side duct flange 2 locations Electrical box FLOOR STANDING NFFL type Water drain You can connect the drain pipe either the right or left side Air intake grille air intake Air outlet Air outlet grille...

Страница 6: ...to 26 C DRY Used for dehumidifying without changing the room temperature temperature range 18 to 30 C COOL Used for normal cooling operation temperature range 18 to 30 C FAN Used to run the fan only...

Страница 7: ...he same time When the batteries are replaced the address setting returns to ALL and so please make the setting again H A C SENSOR button When you press this button use a small tipped object such as a...

Страница 8: ...or more seconds when the batteries have been replaced appears on the display and the ventilation fan can be used O Remote control sensor This detects the temperature around the remote control unit wh...

Страница 9: ...ted by the wireless remote control units have been installed in the same room G SWING button When this button is pressed the airflow sweeps up and down automatically H FILTER lamp This lamp lights to...

Страница 10: ...ed the UNIT button is used first to select a unit Then use the FLAP button to set the airflow direction to a specific angle or to sweep STEP 6 To stop the air conditioner Press the operation button ON...

Страница 11: ...Use a pointed implement to press the ACL button The batteries last about a year depending on how much you use the wireless remote control unit Replace the batteries when the wireless remote control un...

Страница 12: ...or inverter system For further details contact your dealer When mounting the wireless remote control unit on a wall for use Before mounting the wireless remote control unit on the wall place the unit...

Страница 13: ...reless remote control unit s display The buzzer sounds if the address displayed matches the signal receiver s address The buzzer always sounds if ALL appears as the address display If ALL appears as t...

Страница 14: ...e set to any position For positions 1 2 and 3 set the knob upward 1 conversely for 4 5 and 6 set the knob downward ON NK2FL NK1FL type Position of address switch on operation area inside indoor unit T...

Страница 15: ...t Opeartion Press the Emergency operation button The air conditioner initiates a cooling operation when its operation is started up at a room temperature of 24 C or above Conversely it initiates a hea...

Страница 16: ...initiates a heating operation when its operation is started up at a room temperature below 24 C ON OFF TEST Shutdown Set the ON OFF operation switch to OFF NOTE 1 Press the Emergency operation button...

Страница 17: ...nes Do the indication lamps show a cooling heating mismatch or is the auto cooling heating function not available Change the operation mode Auto cooling heating or heating appears on the display even...

Страница 18: ...erature range 17 to 27 C HEAT Used for normal heating operation Only for heat pump type temperature range 16 to 30 C DRY Used for dehumidifying without changing the room temperature temperature range...

Страница 19: ...y mode if the flaps are set in a downward position condensation may form and drip around the vent Do not move the flap with your hands This function is available only for models NKFL NK1FL NK2FL NPFL...

Страница 20: ...is running If is shown on the display of the remote control unit when the VENTILATION button is pressed this indicates that the ventilation fan is not connected O Remote control sensor Normally the te...

Страница 21: ...utton is pressed for more than 4 seconds the TEST indicator appears Then press the ON OFF operation button to start test run H This is displayed to indicate that the system controller is being used fo...

Страница 22: ...ted the fan speed switches automatically STEP 4 Setting the temperature Use the or button as appropriate to change the temperature setting as desired reduces the temperature and increases the temperat...

Страница 23: ...ontrol Simultaneous operation of multiple units Group control Group control is suitable for air conditioning of a large room using multiple air conditioning units One remote control unit can control u...

Страница 24: ...the swing operation Press the FLAP button to set the flap vertical airflow flap to the downward position and then press the FLAP button again This displays and the airflow automatically swings up and...

Страница 25: ...unt it with the arrow facing outward Ceiling mounted type NPFL A Vertical directions automatic This air conditioner is equipped with an auto flap You can set the airflow direction to a specific angle...

Страница 26: ...he horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right Floor standing type NFFL NFMFL It is possible to change the airflow direction Remove the air...

Страница 27: ...r unit number under group control Set the airflow direction for the indoor unit that is shown on the display Each time UNIT is pressed the indicator changes in the order shown below When nothing is di...

Страница 28: ...icator appears on the display until defrosting is completed Heating operation then restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in...

Страница 29: ...F cycle timer Use this mode to always turn off the unit automatically after a preset time elapses ON timer Use this mode to start the unit automatically after a preset time elapses When two remote con...

Страница 30: ...he time using the or button 4 Press the SET button to set the OFF cycle timer When the OFF cycle timer is set the unit will always stop after 3 5 hours of operation How to set the ON timer Example Sta...

Страница 31: ...r particles from the air and should be cleaned at regular intervals as indicated in the table below or when the filter indication on the display of the remote control unit wired type shows that the fi...

Страница 32: ...in mind the dangers that these parts and areas pose and proceed with the work carefully 4 Remove the air filter attached to the air intake grille 2 way semi concealed type NK2FL Grasp the intake grill...

Страница 33: ...he tab up gently Hold the air filter by the tab at the bottom and pull downward When replacing the filter make sure that the FRONT mark is facing you Push it up until you hear it click back into posit...

Страница 34: ...ipe it clean Also clean the drain filter in the same way as the air filter Floor standing type NFMFL Remove the screws open the front panel and then remove any dirt accumulated inside the drain pan an...

Страница 35: ...or many people in room 2 Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ens...

Страница 36: ...WEEE USER MANUAL...

Отзывы: