Operation
00: Unavailable Health airflow function;
01: Available Health airflow function.
(3) Mode Setting (Only valid for part of models):
After entering the advanced setting, press the Fan key to
change the function from A to b, The function code 01 display
in the clock display area flashes. The mode setting function
can be inquired or adjusted.
00: IntelHDry +CFan
01: Auxiliary heating (reserved) +HDry +CFan
02: Dry +CFan
03: HDry +CFan
04: HCFan
(4) The way of humility collection (Only valid for part of
models):
After entering the advanced setting, press the Fan key to
change the function from A to b, The function code 01 display
in the clock display area flashes. Press Up/Down key to
change the function code to 12, At this time press SET key to
confirm. The function code 12 display in the clock display area
statically, and the detailed information in the timing display
area flashes. Press the Up/Down key to change the content
and the SET key to confirm.
00: Collect data from humidity sensor of wired controller
01: Collect data from humidity sensor of indoor PCB