SELECTION OF INSTALLATION LOCATION (Refer Fig.9):  

Select the location for installation to assure adequate 
support of the air conditioner weight and minimum operating
nose and vibrations.

INSTALLATION INSTRUCTIONS.

Installation of wooden frame: 

(Refer Fig. 10, 11, 12)

Inside dimensions of the wooden frame for the
various models shall be as outlined in the following 
table, referring to Fig. 11 and 12.
Position and fasten the wooden frame in the wall 
opening.
Fill in any open spaces between wall opening and 
frame with waterproof cement.
Verify, after cement has dried, that the frame is 
stable and well secured in the place.

I n s t a l l a t i o n      a n d      M a i n t e n a n c e      I n s t r u c t i o n s

ROOM   AIR   CONDITIONER

SERIES

MAY

Whenever possible, install the air conditioner on the
wall of the narrow side of the room.
In order to facilitate easy access to the control of the
air conditioner, the recommended elevation of the 
installation is 180 cm from the floor.  In addition, 
make sure to maintain a minimum clearance of 15 cm 
from any wall, floor or ceiling.
The wall opening should be suitable for enclosing a 
wooden frame for installation and fastening the unit.
Thus, the location on the wall shall be carefully 
considered, it must be free of any columns, trusses 
or beams, as well as any plumping or electrical 
installations.
Never obstruct the air flow of the indoor unit by way of 
the curtains, furniture or partitions of any kind.
The exterior air outlet must never be channelled into
closed spaces such as garages, basements etc.  Keep 
a minimum clearance of 15 cm around the unit and 
50 cm at the back.
Avoid installation of the air conditioner in locations 
affected significantly by solar radiation or by any heat 
sources such as furnaces, heating elements of any 
kind etc.
  

 

A

490

660

B

325

400

C

550

640

D

250

330

a

500

670

b

332

408

a

500

670

cma

x

250

300

Unit Dimensions (mm)

Wooden Frame

Dimensions (mm)

MANUAL MENU

Содержание May series

Страница 1: ...to the cord may result in serious electrical shock PRECAUTIONS Do not use the air conditioner for purposes other than cooling or heating the room Such as drying clothes preserving foods keeping animals or cultivating vegetables Do not block the air intake or outlet vent Such actions causes lowered performance and irregular operation Do not insert any objects into these vents to avoid the danger of...

Страница 2: ...the temperature uniform Adjust the airflow control direction to achieve the optimum uniformity in room temperature Make sure the doors and windows are closed Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Contaminated air filter reduce the airflow and lower cooling and dehumidifying capacity Clean at least once a month Avoid usin...

Страница 3: ...he air filter 1 Main filter removal and cleaning see Fig 4 5 7 8 To remove the main filter hold the handle at the bottom and pull down see Fig 4 Remove the 2 purifying filter frames from the main filter see Fig 5 Rinse the main filter on both sides in lukewarm tape water and allow it to dry not in direct sunlight Attache the 2 purifying filter frames back to the main filter Reinstall it in the ope...

Страница 4: ... control of the air conditioner the recommended elevation of the installation is 180 cm from the floor In addition make sure to maintain a minimum clearance of 15 cm from any wall floor or ceiling The wall opening should be suitable for enclosing a wooden frame for installation and fastening the unit Thus the location on the wall shall be carefully considered it must be free of any columns trusses...

Страница 5: ...ot be left as in Fig 12 but should be chamfer outside to allow proper air movement as shown in Fig 13 IMPORTANT NOTE See Fig 12 and 13 1 Inside 2 Outside 3 Maximum wall thickness C 4 Lateral opening Fig 13 Remove the fresh air handle 1 Remove the 2 screws 4 located on the sides of the plastic front see Fig 14 Remove the plastic front pulling the bottom part and disengaging the upper part upward se...

Страница 6: ...em to the cabinet with screws Set the supports tightly against the outside wall and tighten screws permanently Install the foam seal 3 enclosed with air conditioner between the frame and the cabinet providing a good seal between the interior and the exterior Install the drain as outlined in the section Drain Installation CABINET INSTALLATION IN WALL See Fig 17 1 Front panel 2 Cabinet 3 Foam seal 4...

Страница 7: ... front the screws and the control knobs 2 Demonstrate operation of the air conditioner to the customer and explain all its functions 3 Explain filter removal cleaning and re installtion FINAL TASKS I n s t a l l a t i o n a n d M a i n t e n a n c e I n s t r u c t i o n s ROOM AIR CONDITIONER SERIES MAY The conditioner is to be installed according to all professional rules as well as the standard...

Отзывы: