Set the function control switch to “Off”.
Insert the power plug, and turn on the power of the unit.
Turn the temperature control switch to position to “10” (the coolest) 
and make preparations for other operations.

3

High Cool

Turn the function selector switch to “Hi Cool”  then the  unit automatically conducts 
the high cool operation, so that the room temperature is reduced rapidly and at 
the same time the room is being dehumidified and dust is being filtered.

Low Cool

Turn the function selector switch to “Low Cool” and the unit automatically 
conducts calm cooling operation and  eliminate dust from the room.

Temperature Adjustment

After turning on the unit, adjust the temperature controller when the room 
temperature reduces to the point you desire.  Slowly turn the knob from the 
coolest point “10”.  The compressor will stop operating when a “click” sound is 
heard, indicating that further cooling will stop.  The temperature controller 
automatically turns on the unit for cooling after the room temperature has 
gradually increased, and the temperature controller turns off the cooling 
operation when the room temperature reduces to that you choose.

Note:

O

Adjust the temperature controller until you feel comfortable (normally 26 - 30 C).

After the temperature controller is adjusted, remember that the temperature control 
knob  can not be adjusted clockwise within 3 minutes, otherwise the compressor 
will be burnt out.

PREPARATIONS FOR OPERATION

COOLING OPERATION

COOLING OPERATION

SELECTOR

Hi Cool

Lo Cool

Hi Fan

Lo Fan

Off

THERMOSTAT

SELECTOR

Hi Cool

Lo Cool

Hi Fan

Lo Fan

Off

1

C

o

o

l

THERMOSTAT

SELECTOR

Hi Cool

Lo Cool

Hi Fan

Lo Fan

Off

2

3

4

5

6

7

8

9

10

RCA INST MANUAL

Содержание MAY 110

Страница 1: ...Owner s Manual High Quality Window Type Room Air Conditioner MAY 110 RCA INST MANUAL...

Страница 2: ...ponents 2 Control Panel 2 Preparations for Operation 3 Cooling Operation 3 Fan Operation 4 Airflow Direction Adjustment 4 Operation Maintenance and Care 5 Replacing the filter 5 Precautions 6 Before c...

Страница 3: ...lso flower pollen bacteria nicotine acarus and other harmful airborne substances This greatly increased the degree of air cleanness To prevent accidents make sure to install a fuse for the external po...

Страница 4: ...ntrol switch Offl Stop all operation Lo Fan Fan only operation Air delivery at low speed Hi Fan Fan only operation Air delivery at high speed Lo Cool Cooling operation at low speed Hi Cool Cooling ope...

Страница 5: ...nt you desire Slowly turn the knob from the coolest point 10 The compressor will stop operating when a click sound is heard indicating that further cooling will stop The temperature controller automat...

Страница 6: ...low speed and the compressor will stop operation except that the slight wind ventilate the air and eliminate dust Adjust the horizontal grille Move the adjustment plate to direct the air flow up down...

Страница 7: ...e filter must be purchased from authorized dealer Note that the model number in the package of the filter must conform to that you use Remember the following suggestions so as to improve the cooling e...

Страница 8: ...power plug and the lead are overheating during the unit s operation if the outer covering of the wire is damaged if foreign objects enter into the air conditioner If the water suddenly splashed on th...

Страница 9: ...h window curtain etc Is the door or window open Close the entrance exit of the window Are there any obstacles blocking the ventilation of the air inlet or outlet of the air conditioner Remove the obst...

Страница 10: ...ces on the parkSuite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE Suite 3 19 Darby...

Отзывы: