background image

ELB

Power

Breaker

L N

L N

F1 F2 R1 R2

L

N

F1

F2

P1

P2

Ground wiring

Power supply wiring

Terminal block(7P)

ELB: Electricity Leakage Breaker

Power        Main    R/C

Supply       Bus      Wiring

220~240V AC

50Hz

Electrical characteristics

Specifications for field supplid ELB and wire

Unit

Power supply

Fan motor

Model

Hz

Volts

MCA

MFA

KW

FLA

KXV021

50

220~240

0.77

16

0.15

0.47

KXV024

0.77

16

0.15

0.47

KXV030

0.86

16

0.17

0.54

0.86

16

0.17

0.54

KXV036

MCA : Min. Circuit Amps (A)

MFA  : Max. Fuse Amps(A)

KW   : Fan Motor Rated output(KW) 

FLA  : Full Load Amps(A)

NOTE

  All field supplied parts and materials and electrics works must conform to local codes.

  Use copper wire only.

� 

 

All wiring must be performed by an authorized electrician.

  Every indoor unit must have a sub circle breaker and the whole system must have a main circle breaker.

� 

 

Be sure to ground the air conditioner.

  The appliance shall be installed in accordance with national wiring regulations , and shall be provided to ensure all-poled is connection from the 

supply mains, and distance between the poles shall be more than 3 mm.

Model

Power supply wiring

Remote controller wiring

Main bus communication wiring

Field ELB

Wire and Size

Wire

Size

KXV021

16A

Must comply

with maximum

current and local

codes(0.75mm

2

)

Twisted-pair

wires

1.0mm

2

KXV024
KXV030

KXV036

CHECK ITEMS

BEFORE POWER ON

■  Is there any gas leakage at flare nut connections?

■  Has the heat insulation been carried out at flare nut connection? 

■  Is the connecting cable being fixed to terminal board firmly? 

■  Is the connecting cable being clamped firmly?

■  Is the drainage ok? (Refer to "Drainage test  section) 

■  Is the earth wire connection properly done?

■  Is the indoor unit properly hooked to the installation plate?

■  Is the power supply voltage complied with rated value?

AFTER POWER ON

■  Is there any abnormal sound?

■  Is the cooling operation normal?

■  Is the thermostat operation normal?

■  Is the remote control's LCD operation normal?

     NOTE:

     For the piping and wiring methods,leakage test,vacuum process and installation setting 

     through HMI, please refter to “Outdoor unit Installation Manual”.