pumping solutions for all applications
MAN_5501
Revision: 7.0
Status: Approved
Issue Date: 08/06/2021
Page 14 of 26
Airwell Group Pty Ltd | Evaporative pump ES0023
Fit anchoring rope(s) to the angles (brackets) that support the floats,
in order to secure the pump to the desired pumping location.
-
Connect the airline to the controller (se
e the manual “Controllers”)
Vessel under pressure
Airline must be equipped with a high-pressure discharge valve limited to 145PSI
(
≈1000KPA) (≈10bar).
Over pressurized airline or vessel may explode causing serious injury or even death.
-
Make a final check to all connections and fittings.
-
Tape the airline and the water line together at about 3 turns per 1m intervals.
Note:
Do not tape over stainless pump as this is bad for corrosion.
Lift the pump by the poly float units and launch it into the water.
Note: Do not pull on the cable kit alone.
Caution
Under no circumstances attempt to use this pump as a passenger vessel.