11-6
CONTROL SYSTEM
SM DEL60Hz 1-E.0 GB
11.7.2
Indoor Coil over Heating Protection
ICT
ICT Trend
Fast
Decreasing
Decreasing
No Change
Increasing
Fast
Increasing
ICT > 55
SC
SC
SC
SC
SC
53 < ICT
≤
55
D1
D1
D2
D2
D2
49 < ICT
≤
53
SR
SR
D1
D2
D2
47 < ICT
≤
49
SR
SR
SR
D1
D2
45 < ICT
≤
47
Norm
Norm
SR
SR
D1
43 < ICT
≤
45
Norm
Norm
Norm
SR
SR
ICT
≤
43
Normal
11.7.3
Compressor over Heating Protection
Compressor temperature can be in one of 5 control zones (4 in protection, and 1 normal),
according to the following chart.
Control Status
Compressor
Temperature Increases
Else
P1
Norm
SR
P2
D1
SR
P3
D2
D1
Stop Compressor
SC
Normal
P1
P2
Stop-Compresor
CTTOH1
CTTOH2
CTTOH3
CTTOH4
CTT
P3