CHARACTERISTIC  OF  TEMPERATURE  SENSOR 

 

Portable MAF                                                                  28                                                      Version - 0

 

 

 

 

11 Characteristic of temperature sensor   

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Temp.

 

Resistance 

KΩ 

Temp.

 

Resistance 

KΩ 

Temp.

 

Resistance 

KΩ 

-10 

62.2756 

17 

14.6181 

44 

4.3874 

-9 

58.7079 

18 

13.918 

45 

4.2126 

-8 

56.3694 

19 

13.2631 

46 

4.0459 

-7 

52.2438 

20 

12.6431 

47 

3.8867 

-6 

49.3161 

21 

12.0561 

48 

3.7348 

-5 

46.5725 

22 

11.5 

49 

3.5896 

-4 

44 

23 

10.9731 

50 

3.451 

-3 

41.5878 

24 

10.4736 

51 

3.3185 

-2 

39.8239 

25 

10 

52 

3.1918 

-1 

37.1988 

26 

9.5507 

53 

3.0707 

35.2024 

27 

9.1245 

54 

2.959 

33.3269 

28 

8.7198 

55 

2.8442 

31.5635 

29 

8.3357 

56 

2.7382 

29.9058 

30 

7.9708 

57 

2.6368 

28.3459 

31 

7.6241 

58 

2.5397 

26.8778 

32 

7.2946 

59 

2.4468 

25.4954 

33 

6.9814 

60 

2.3577 

24.1932 

34 

6.6835 

61 

2.2725 

22.5662 

35 

6.4002 

62 

2.1907 

21.8094 

36 

6.1306 

63 

2.1124 

10 

20.7184 

37 

5.8736 

64 

2.0373 

11 

19.6891 

38 

5.6296 

65 

1.9653 

12 

18.7177 

39 

5.3969 

66 

1.8963 

13 

17.8005 

40 

5.1752 

67 

1.83 

14 

16.9341 

41 

4.9639 

68 

1.7665 

15 

16.1156 

42 

4.7625 

69 

1.7055 

16 

15.3418 

43 

4.5705 

70 

1.6469 

Содержание AWPO-MAF009-C11

Страница 1: ...Portable MAF Series Models AWPO MAF009 C11 AWPO MAF012 C11 REFRIGERANT R410A COOLONLY REFRIGERANT SM MAF 1 A 1 GB JAN 2014...

Страница 2: ...CONTENTS...

Страница 3: ...Protection function 11 7 4 Fan only mode function requirement 11 7 5 Cooling mode function requirement 11 7 6 Drying mode 12 7 7 Heating mode Optional 13 7 8 Heat pump mode optional 14 7 9 Sensor mal...

Страница 4: ......

Страница 5: ...here is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire of electric shock Always install a dedicated circuit and breaker Improper wiring or...

Страница 6: ...eration the product with wet hands There is risk of fire or electric shock Do not place a heater or other appliance near the power cable There is risk of fire and electric shock Do not allow water to...

Страница 7: ...connect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Take care to ensure that nobody could step on or fall onto the outdoor unit Thi...

Страница 8: ...f product Always insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction...

Страница 9: ...Min Max Pa 0 0 Sound power level 4 H M L dB A 64 65 Sound pressure level 5 H M L dB A 52 49 46 52 48 45 Moisture removal l hr 1 1 2 Condensate drain tube I D mm OUTDOOR Side Refrigerant control Capili...

Страница 10: ...splay Sleep mode Temperature sensor Self diagnosis and auto protection function Anti freezing control in cooling or drying mode Prevent the water being freezed on evaporator by sensing the evaporator...

Страница 11: ...AUTO to COOL to DRY to FAN An indicator light will illuminate for each mode setting Timer button Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the buttons...

Страница 12: ...DIMENSION Portable MAF 8 Version 0 4 Dimension Unit Dimension W mm H mm D mm Single hole 467 765 397...

Страница 13: ...elow is a brief description of the important components and their function in what is called the refrigeration system This will help to understand the refrigeration cycle and the flow of the refrigera...

Страница 14: ...ELECTRONIC FUNCTION Portable MAF 10 Version 0 6 Wiring Diagram...

Страница 15: ...7 4 Fan only mode function requirement 7 4 1 The compressor and outdoor fan are OFF at Fan only mode except P1 protection 7 4 2 The speed of indoor fan can be optionally chosen as High Mid Low 7 4 3...

Страница 16: ...an will stop after delaying for 5seconds If it operates at heating mode the outdoor fan will be off delaying for 30 seconds 7 5 4 Power management for power management models Entering into the only co...

Страница 17: ...6 3 Power management for power management models Entering into drying mode indoor fan motor operates immediately and keeps moving for 30 minutes at lease Compressor operates and indoor fan motor keep...

Страница 18: ...mp mode is invalid and water pump indoor motor outdoor motor compressor shaded pole motor stop When TA 6 heat pump mode resumes to be valid 7 8 2 At non defrosting situation shaded pole motor always s...

Страница 19: ...e valid at the heat pump mode 7 8 9 Non defrosting motion for power management models The unit enters into the heat pump mode for the first time four way valve opens When compressor shuts off the four...

Страница 20: ...INTERNAL STRUCTURE Portable MAF 16 Version 0 8 Internal Structure...

Страница 21: ...INTERNAL STRUCTURE Portable MAF 17 Version 0...

Страница 22: ...INTERNAL STRUCTURE Portable MAF 18 Version 0...

Страница 23: ...filter out along the arrow direction and then take the filter down Remove the lower filter by loosening the screw taking down the air filter as shown in Figure see below Cleaning Wash the air filter b...

Страница 24: ...uld drain out See below Figure Keep the appliance running on FAN mode for half a day in a warm room to dry the appliance inside and prevent mold forming Stop the appliance and unplug it wrapped the co...

Страница 25: ...pressor terminal box cover and disconnect wires from terminals Using an ohmmeter check continuity across the following Terminal C and S no continuity Open winding replace compressor Terminal C and R n...

Страница 26: ...normal low side pressure C Low temperature difference across coil The compressor valves are faulty replace the compressor 10 1 4 Terminal overload external Some compressors are equipped with an exter...

Страница 27: ...overload will automatically reset but may require several hours before the heat is dissipated 10 1 7 Checking the internal overload 1 No power to unit remove the leads from the compressor terminals 2...

Страница 28: ...of the system by installing a line tap on the process tube Apply gauge from process tube to EPA approved gauges from process tube to EPA approved recovery system Recover CFCs in system to at least 5...

Страница 29: ...he process tube ends 10 2 4 Special procedure in the case of compressor motor burnout 1 Recover all refrigerant and oil from the system 2 Remove compressor capillary tube and filter drier from the sys...

Страница 30: ...h the plugs from the replacement compressor 10 3 Fan motor A single phase permanent split capacitor motor is used to drive the evaporator blower and condenser fan A self resetting overload is located...

Страница 31: ...om unit 2 Check for visual damage such as bulges cracks or leaks 3 For dual rated apply an ohmmeter lead to common C terminal and the other probe to the compressor HERM terminal A satisfactory capacit...

Страница 32: ...36 51 3 3185 2 39 8239 25 10 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31...

Страница 33: ...n or to wait until auto running 2 Not cool enough The windows or doors in the room are not closed Make sure all the windows and doors are closed There are heat sources inside the room Remove the heat...

Страница 34: ...EXPLODED BIEW AND PART LIST Portable MAF 30 Version 0 13 Exploded view and part list AWPO MAF009 C11 AWPO MAF012 C11...

Страница 35: ...citor 28 Compressor 2 7 Capacitor of fan motor 29 Supporting bar 2 8 Capacitor box 30 Pipe temperature sensor assembly 3 Dobber 31 Indoor temperature sensor assembly 5 Electronic control box assembly...

Страница 36: ...EXPLODED BIEW AND PART LIST Portable MAF 32 Version 0 SERVICE MANUAL Portable MAF Series...

Отзывы: