TROUBLESHOOTING 

Trouble

 

Probable Cause

 

Remedy 

Paint Will Not 

Flow 

1.  Blockage in fluid nozzle 
2.  Loss of air pressure in cup 

 

3.  Loose fluid nozzle 
4.  Paint hose loose, damaged 

or clogged 

5.  Coating is too thick 
6.  Loose Needle Packing 

1.  Clean or replace; strain paint 
2.  Search for air leaks and 

check cup gasket 

3.  Tighten 
4.  Tighten,  replace or clean; 

strain paint 

5.  Thin the coating 
6.  Replace packing 

Inconsistent 

Spray Pattern 

(Spits And 

Sputters) 

1.  Running out of paint 

 

2.  Loose fluid tube 
3.  Loss of fluid pressure 

 

4.  Loose needle packing 
5.  Damaged air pressure tube 

1.  Fill cup or pot, but never to 

the top (3/4 max.) 

2.  Tighten 
3.  Search for air leaks or 

blockages 

4.  Replace packing 
5.  Air pressure tube requires 

replacing or close inspection 

Leakage at 

Front of Gun 

1.  Damaged fluid needle 
2.  Dirty fluid nozzle 
3.  Impurities in paint 
4.  Loose fluid tube 
5.  Fluid adjustment screwed all 

the way out 

 

6.  Needle not firmly seated in 

the spray head 

7.  Packing too tight 

1.  Replace 
2.  Clean 
3.  Strain paint 
4.  Tighten 
5.  Rotate Fluid Control Knob 

(DT-3012) on rear of gun 

clockwise 

6.  Check for spray head  

obstruction 

7.  Replace Packing 

Distorted 

Spray Pattern 

1.  Dirty or damaged spray head 
2.  Dirty or damaged fluid tube 

or needle 

3.  Fluid tube partially clogged 

1.  Clean or replace 
2.  Clean or replace 

 

3.  Clean 

 

Содержание Gravity MicroFlex MFG-3100

Страница 1: ...Maryland 20794 9425 USA 301 497 7600 800 937 HVLP 4857 Fax 301 497 7613 microflex airverter com www airverter com Compliance Quality Performance Reliability User s Manual Gravity MicroFlex Model MFG...

Страница 2: ...AirVerter Gravity MicroFlex Spray Gun DO NOT OPERATE SPRAY GUNS WITHOUT PERSONAL SAFETY EQUIPMENT...

Страница 3: ...Smith Eastern shall if given prompt written notice by the Purchaser correct such nonconformity by repair or replacement of the nonconforming part F O B Smith Eastern s repair facility Repair parts are...

Страница 4: ...impurities Use a cone strainer or a 100 mesh nylon bag or equivalent strainer 3 Thin your paint according to the manufacturer s specifications 4 Needle packings GG 024 are preset at the factory and s...

Страница 5: ...d a clean soft cloth Use caution to avoid damaging or bending the needle Re lubricate the needle with Vaseline 3 Unscrew the Pattern Control Ring GG 001 from the Spray Head Assembly to separate the Ad...

Страница 6: ...he larger of the two Anti Friction Washers between the Spray Head xxx and the Adapter Collar MFG 002 4 Reattach the Needle Seat to the Spray Head 5 Replace the MicroFlex Adapter Collar Rigid Extension...

Страница 7: ...and free of obstructions 3 All gauges and valves must be clean and in proper working order LUBRICATION INSTRUCTIONS 1 Use Vaseline or a non silicone grease to lubricate the gun 2 Lubricate all threade...

Страница 8: ......

Страница 9: ...AirVerter Gravity MircoFlex Spray Gun Illustrated Parts Breakdown 9...

Страница 10: ...0 01 489 1921 Air Valve Poppet Note 1 O Ring Note 1 Air Valve Spring GG 024 4940 01 490 1897 Needle Seal Cartridge GG 025 4940 01 489 6203 Trigger GG 026 4940 01 490 1880 Air Control GG 027 4730 01 49...

Страница 11: ...d air pressure tube 1 Fill cup or pot but never to the top 3 4 max 2 Tighten 3 Search for air leaks or blockages 4 Replace packing 5 Air pressure tube requires replacing or close inspection Leakage at...

Страница 12: ...AirVerter Gravity MircoFlex Spray Gun Illustrated Parts Breakdown 12 Notes...

Страница 13: ...AirVerter Gravity MircoFlex Spray Gun Illustrated Parts Breakdown 13 Notes...

Страница 14: ......

Отзывы: