22
7.6. Recirculating Option
The Extractor can also be used in recirculation
mode, it must be connected to a filter kit (optional)
and a grill must be installed to recirculate air back
into the kitchen.
8. Electrical Connection
•
The electrical connection must be carried out by
a qualified electrician who is authorised to carry
out such work.
•
Statutory regulations and the connection
specifications issued by the local power supply
company must be strictly observed.
•
When connecting the appliance it must be
ensured that there is a device which makes it
possible to disconnect it from the mains at all
poles with a contact opening width of at least
3mm. Line
-
protecting switches, fuses or
contactors are suitable cut
-
out devices.
When connecting and repairing the appliance
disconnect it from the electricity supply with
one of these devices.
•
The earth wire must be sufficiently long so that
if the strain relief fails, the live wires of the
connecting cable are subjected to tension
before the earth wire.
•
Any superfluous cable must be removed from
the installation area beneath the appliance.
•
Make sure that the local mains voltage is the
same as the voltage on the rating label.
•
Full protection against accidental contact must
be ensured on installation.
ATTENTION:
Incorrect connection may result in the power
electronics being damaged.
•
The hob has been fitted with a temperature
resistant connection cable in the factory.
•
Connection to the mains is carried out in
accordance with the circuit diagram, unless the
connection cable is already fitted with a plug.
•
If the mains cable of this appliance eis damaged
it will need to be replaced with a special
connection cable. In order to avoid any risks,
this must be carried out by the manufacturer.
Single Phase Connection