INSTALLATION 

 

 

 

HORIZONTAL 

The  horizontal  models  have  four  roof  fixing  points. 
Keep  in  mind  to  asure  a  minimum  distance  to  open 
the service panel and to replace the filters. Depending 
on  the  model,  this  distance  is  500mm  (Kleenbox 
46/46  and  Kleenbox  46/76)  or  800mm  (Kleenbox 
76/76). 

 

VERTICAL 

Maintain  300  mm  free  of  obstructions  in  the  inlet 
zone. 

 

 

 

Assembly, connection and disconnection, electrical wiring and maintenance must be 
carried out exclusively by qualified personnel, observing these instructions and in 
accordance with the applicable standards. In case a special control is supplied, a 
specific manual is attached that must be used for its operation and installation. 

 

It is not necessary to remove the service panel to connect the equipment All the 
connections (power and control) and necessary fixings are external (on the lateral of the 
equipment). The equipment has a service panel to carry out repairs and replacements 
(see 

“REPAIRS” section). 

Power supply 

HORIZONTAL 

To  connect  the  power  supply  on  the  horizontal 
model,  the  user  should  find  a  black  connection  box 
(placed  on  the  lateral).  Just  connect  single  phase 
230V to supply the fan. 

 

VERTICAL 

The  vertical  models  include  a  plug&play  wire  which 
should  be  connected  to  the  equipment  and  to  a 

Shucko

 wall connector with electrical current. 

 

 

Control 

 

HORIZONTAL 

There is a white connection box placed on the lateral, 
next  to  the  black  power  supply  box.  It  is  not  needed 
to open the service panel to connect the control. 

It  is  necessary  to  connect  the  fan  0-10V  regulation 
and  the  dirty  filter  visual  alarm  (see  wiring  diagram 
section). 

 

VERTICAL 

For  the  vertical  model,  the  control  is  inbuilt  in  the 
equipment and do not need any kind of installation. 

 

 

 

 

 

230Vx1 
Power Supply 

Control  
connection 

Содержание Kleenbox 46/46

Страница 1: ...e installation Give this manual to the end user SECURITY ADVISE SYMBOLS WELDOM20110 R0 24 02 21 Attention Danger Safety Warning High voltage or electric current hazard Danger of injury Attention Do no...

Страница 2: ...UCTIONS 4 Control board features 4 WIRING DIAGRAMS 4 TECHNICAL DATA 6 MAINTENANCE INSTRUCTIONS 10 Exterior cleaning 10 Internal cleaning 10 REPAIRS AND REEMPLACEMENTS 10 Filter reemplacements 11 Fan r...

Страница 3: ...ower and control and necessary fixings are external on the lateral of the equipment The equipment has a service panel to carry out repairs and replacements see REPAIRS section Power supply HORIZONTAL...

Страница 4: ...ts If the packaging is open cover the purifier to protect it from dust Do not step on or place heavy load son it to avoid damage to he material Storage temperatura between 20 C and 40 C When transport...

Страница 5: ...5...

Страница 6: ...6 TECHNICAL DATA...

Страница 7: ...7...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...t use caustic or acid containing detergents Internal cleaning In models with perforated grille it is advisable to clean the inside of the unit with a vacuum cleaner at least once every 2 years better...

Страница 11: ...hey are opened take off the panel using the handle Filter reemplacements Both models include a visual dirty filter alarm When the led is turned ON the H14 HEPA filter must be changed the lifetime of H...

Страница 12: ...space to take off the H14 filter This one is fixed to the housing by four wing nuts that should be untighten before remove the filter HEPA H14 Filter To place the filters inside the equipment follow...

Страница 13: ...rs to get more working space and avoid damages to them Straightaway disconnect the fan wires Depending on the model we have Kleenbox Horizontal Power supply black box faston 0 10V regulation white box...

Страница 14: ...tion It has four hexagonal screws To assemble the new fan follow the same steps in reverse order ACCESSORIES Optional accessories not included for the Kleenbox installation Protection panel for HEPA f...

Страница 15: ...15 DECLARATION OF CONFORMITY...

Страница 16: ...that eventually suffer failures attributable to production defects Installation costs are borne by the buyer Products that in our opinion have been used improperly handled incorrectly improperly inst...

Отзывы: