LOOP MODEL DESIGN (Fig.1)
LOOP series extraction fan includes body
1
with mounted motor and propeller.
Control plate is mounted in the central
flow section (protected by cover
3
,
mounted with screws
4
). Part
5
is fixed to
the front part of the body and serves to
insert the power supply cable. Power
supply cable is protected by the cover
2
.
The device and the inlet are protected by
masking front
6
.
Preparations for fan mounting should
start with taking off the masking front
6
(snap-in mounted)and cover
2
. Next,
power supply cable opening should be
made in part
5
. Last preparation step
before mounting the fan is driving screws
4
to make it possible to take cover
3
off
and access control plate with power
terminals.
Warning !!!
LOOP WL100R, WL125R model has a movement detection sensor attached with a tape to cover
3
-
remain cautious not to damage the connecting tape (it is recommended to take the cover off after mounting
the fan in the ventilation duct).
MOUNTING INSTRUCTIONS
• place the prepared fan body in a
ventilation duct - mark mounting
openings
• make openings for anchors and
space them equally to the openings
on the fan body
• place the fan in the ventilation duct,
inserting the power cable through
the opening made in the body
beforehand
X
Y
Z
W
D
C
A
B
Ø
LOOP
Ø100
Ø125
Operating Range
I
II
I
II
Capacity [m³/h]
55
85
120
165
Power [W]
3,3
4,6
7
10
Power supply [V]
230
Rated Frequency [Hz]
50
Protection Rating
IPX4
Fig. 1
2
6
1
3
4
5
INDEX
Ø X Y A B C D Z W
LOOP WL100 100
160
160
125
125
109
109
76
102
LOOP WL125 125
200
200
153
153
137
137
77
102