LOOP MODEL DESIGN (Fig.1) 

LOOP series extraction fan includes body 

1

 with mounted motor and propeller. 

Control plate is mounted in the central 

flow section (protected by cover 

3

mounted with screws 

4

). Part 

5

 is fixed to 

the front part of the body and serves to 

insert the power supply cable. Power 

supply cable is protected by the cover 

2

The device and the inlet are protected by 

masking front 

6

.

Preparations for fan mounting should 

start with taking off the masking front 

6

 

(snap-in mounted)and cover 

2

. Next, 

power supply cable opening should be 

made in part 

5

. Last preparation step 

before mounting the fan is driving screws 

4

 to make it possible to take cover 

3

 off 

and access control plate with power 

terminals. 

Warning !!!

 LOOP WL100R, WL125R model has a movement detection sensor attached with a tape to cover 

3

 - 

remain cautious not to damage the connecting tape (it is recommended to take the cover off after mounting 

the fan in the ventilation duct).

MOUNTING INSTRUCTIONS 

•  place  the  prepared  fan  body  in  a 

ventilation duct - mark mounting 

openings

•  make  openings  for  anchors  and 

space them equally to the openings 

on the fan body

• place the fan in the ventilation duct, 

inserting the power cable through 

the opening made in the body 

beforehand

X

Y

Z

W

D

C

A

B

Ø

                LOOP 

Ø100 

Ø125

Operating Range 

II 

II

Capacity [m³/h] 

55 

85 

120 

165

Power [W] 

3,3 

4,6 

10

Power supply [V] 

 

230

Rated Frequency [Hz] 

50

Protection Rating 

IPX4

Fig. 1

2

6

1

3

4

5

    

INDEX

     

Ø X Y A B C D Z W

     LOOP WL100   100 

160 

160 

125 

125 

109 

109 

76 

102

     LOOP WL125   125 

200 

200 

153 

153 

137 

137 

77 

102