ACR60   
ACR60LV  

 

Installation and Wiring Instructions 

 
 

All wiring to be in accordance with the current I.E.E. Regulations, or 
the appropriate standards of your country and 

MUST 

be installed 

by a suitably qualified person. 
The Fan should be provided with a local isolator switch capable of 
disconnecting all poles, having a contact separation of at least 
3mm. 
Ensure that the mains supply (Voltage, Frequency, and Phase) 
complies with the rating label. 
The Fan should only be used in conjunction with the appropriate 
Airtech products. 
The fan should only be used in conjunction with fixed wiring. 
When the Fan is used to remove air from a room containing a fuel-
burning appliance, ensure that the air replacement is adequate for 
both the fan and the fuel-burning appliance. 
The Fan should not be used where it is liable to be subject to direct 
water spray for prolonged periods of time. 
Where ducted Fans are used to handle moisture-laden air, a 
condensation trap should be fitted. Horizontal ducts should be 
arranged to slope slightly downwards away from the Fan. 
This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 
Young children should be supervised to ensure that they do not 
play with the appliance. 
 

This product should not be disposed of with household waste.  Please recycle where facilities exist.  Check with 
your local authority for recycling advice. 

 

IPX4 

SAFETY AND GUIDANCE NOTES 

Содержание ACR60

Страница 1: ...adequate for both the fan and the fuel burning appliance The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time Where ducted Fans are used to h...

Страница 2: ......

Страница 3: ...gh the holes in the fan back plate Drill plug and screw into position Attach ducting as required for the installation 4 Wire the fan as described in the Wiring section Adjust any settings as required...

Страница 4: ...re the fan first remove the grille With the grille removed the control board is visible Fig 7 Do NOT isolate the fan from the power supply as configuration requires power to the fan removing the grill...

Страница 5: ...t is 15 minutes Humidity level trigger The humidity setting defines at what relative humidity the fan will trigger adjustable from 50 to 70 rH Comfort mode Comfort mode changes how the fan boosts Norm...

Страница 6: ...d boost pulling the pullcord will first enter boost a further pull will return the fan to trickle Data Logger ACR60 model With the fan powered up upon removing the cover the display will automatically...

Страница 7: ...its 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life bearings which do not require lubrication 1 The fan continuously runs in boost a Cause i The room is damp...

Страница 8: ...et b Solution i This is normal and the fan is designed to handle condensation build up However a condensation trap connected immediately after the fan will help to prevent water dripping into the room...

Страница 9: ...0V Controller Fan 12V D C SELV Supply N L LS LS N L 2 1 3 Fig 5 Continuous boost 1 with no trickle facility ACR60LV model Fig 4 Continuous trickle with pullcord boost ACR60LV model N L 1 Phase Supply...

Страница 10: ...Fig 6 Continuous trickle with boost facility via LS or internal pullcord ACR60LV model N LS 12V 0V Controller Fan 12V D C SELV Supply N L LS LS N L 2 1 3 24v D C 24V 0...

Страница 11: ...y 1 Loosen the screw at the bottom of the grille 2 Pull the grille clear of the screw and lift away Circuit board cover DO NOT REMOVE Control Board INCREASE Value REDUCE Value MODE Button Note ACR60 m...

Страница 12: ...AIRTECH ENVIRONMENTAL SYSTEMS STATHE ROAD BURROWBRIDGE SOMERSET TA7 0RY Tel 0800 378 017 477775 A 1117...

Отзывы: