Exterior
6-8
2021 Classic
The mating, green swivel nut and brass nipple also
incorporate new features: the green nylon nut swivels
on a black bushing that is heat-sensitive� Between 240
and 300°F, the bushing will yield (melt) allowing the
spring-loaded module in the valve to push the brass
nipple back (approximately 1/4 in�), closing the module
and stopping the flow of gas from the cylinder. Inside
the brass nipple is a flow-limiting device designed
to sense excessive gas flow. If an excessive flow is
sensed, the flow-limiting device shuts the flow down
to a maximum of 10 SCFH (Standard Cubic Feet per
Hour) or less� This is also referred to as the bypass
flow.
Bypass flow is extremely important in the proper
operation of this connection. The flow-limiting device
may activate if the cylinder valve is opened quickly�
When all appliances are off, the bypass flow allows
the pressure downstream from the flow-limiting device
to equalize. When pressure is equalized, the flow-
limiting device will supply normal flow to the system.
Equalization occurs in approximately 5 seconds and,
in most cases, goes completely unnoticed� If, however,
an appliance is left on or there is a leak or open flow
in the system, the bypass pressure will not be able to
equalize and allow the flow-limiting device to re-open.
Symptoms of this condition would be appliances that
light but have lower than normal flame or starve out
from lack of gas, a substantial reduction in the flame
when another appliance is operating, or pilots that are
difficult to light. If this should happen, the following
steps should eliminate the condition:
1� Close LPG cylinder valve�*
2� Extinguish all flames and smoking materials.
3� Be sure all gas appliances, including their pilot
lights, are off�*
4� Open LPG cylinder valve slowly� Do not snap open�
5� Wait at least 15 seconds before lighting appliances�
6� If operational difficulties continue, there may be
a leak in the system� Immediately close the LPG
cylinder valve and have the system inspected by a
qualified RV service technician.
*When reconnecting a full cylinder to an auto
changeover regulator, it is not necessary to shut off the
appliances or close the valve of the cylinder already in
service�
The amount of time a full tank of gas will last is
dependent on usage� In cold weather, when you are
using the furnace, large amounts of hot water, and are
doing extensive cooking, you will naturally use more
than you will in warm weather when you may do limited
cooking� On the average, with normal cooking and
other appliance use, you can probably count on two to
three weeks of service from each tank�
WARNING
Leaking LPG may ignite, causing a fire or
explosion, which could result in serious bodily
injury, property damage, and/or death.
Automatic Gas Regulator
All models are equipped with a two stage automatic
change-over gas regulator that offers the convenience
of automatic changeover from empty to full gas
cylinders� Both tanks are connected to this regulator�
Make sure there is propane in both tanks before you
start� Rotate the white knob on the top-front side of
the regulator toward the cylinder you want to use first.
This will be the
service
cylinder and the other will be
the
reserve
cylinder� Slowly open both cylinder valves�
Open both cylinder valves completely, then close about
1/4-turn� This will allow you to easily check to see if
valves are open or closed� The indicator on top of the
regulator will turn bright green� The indicator will stay
bright green as long as there is fuel coming from the
service cylinder� When the service cylinder empties,
the regulator will automatically draw fuel from the
reserve cylinder, providing an uninterrupted fuel flow
to the system� When it switches over, the indicator will
change from green to red� This red color indicates the
service cylinder is empty and needs to be filled.
WARNING
LPG regulators must always be installed with the
diaphragm vent facing down. Regulators that are
not located in compartments have been equipped
with a protective cover. Make sure the regulator
vent faces down and the cover is kept in place
to minimize vent blockage, which could result in
excessive gas pressure, causing fire or explosion.
Содержание CLASSIC 2021
Страница 1: ...2 0 2 1 C L A S S I C Owner s MANUAL ...
Страница 4: ...2021 Classic NOTES NOTES ...
Страница 6: ...2021 Classic 1 2 Introduction NOTES NOTES ...
Страница 28: ...2021 Classic 4 4 NOTES NOTES Floor Plans And Specifications ...
Страница 84: ...Maintenance 8 16 2021 Classic Electrical Diagrams 12 Volt Main Schematic ...
Страница 89: ...Maintenance 2021 Classic 8 21 Multiplex Controls Switch Panel Layout 30 ...
Страница 90: ...Maintenance 8 22 2021 Classic Switch Panel Layout 33FB ...
Страница 95: ...Maintenance 2021 Classic 8 27 Fresh Water Layouts 30 Classic ...
Страница 96: ...Maintenance 8 28 2021 Classic Fresh Water Layout 33FB Classic ...
Страница 100: ...2021 Classic 8 32 Maintenance NOTES NOTES ...
Страница 104: ...428 West Pike Street P O Box 629 Jackson Center OH 45334 0629 Phone 937 596 6111 Fax 937 596 6539 www airstream com ...