SPECIAL SMOKE ALARM FEATURES
If your smoke alarm has one or more of these special features, read the following:
•
BLINKING LED LIGHT (Models B, C, E and PB): The indicator light under
the Push-to Test button blinks about once per minute to indicate the smoke
alarm is receiving power.
WARNING
: Very thick smoke may obscure the light.
LP GAS DETECTOR
The LP gas detector is located approximately six inches above the floor. LP gas is a
mixture of gases produced and sold commercially as a fuel for heating and cooking
appliances. LP gas is highly flammable and, as a result, can be explosive if ignited
under certain circumstances. LP gas is heavier than air and, if confined in a closed
space, will accumulate close to the floor. When the LP gas concentration in your unit
exceeds 2000 PPM the detector will provide a visual and audible alarm by sounding a
buzzer and flashing the red LED two times per second.
WARNING
: Activation of this detector indicates the presence of LP gas,
which can cause an explosion and/or fire. This normally indicates a leak in the
LP gas installation or a LP gas appliance. Extinguish all open flames, open your
windows and door and evacuate the unit immediately. Do not activate any electri-
cal switch. Turn off the LP at your gas bottle(s). DO NOT RE-ENTER YOUR UNIT
UNTIL A QUALIFIED REPAIR TECHNICIAN HAS CORRECTED THE PROBLEM OR
A FIRE DEPARTMENT OFFICIAL HAS CLEARED YOUR UNIT AS SAFE.
OPERATION
Your LP gas detector is wired directly to your vehicle battery and incorporates a 1-amp
in-line fuse located inside the roaside console.. When the device is operating normally
the green LED will be lit.
WARNING
: It is not recommended that the detector be disconnected
from the battery during periods of storage. There is a small heater on the sensor
of the device, which “burns” away impurities in the air during periods of normal
use. During periods when power is interrupted, impurities can build up on the
sensor. When power is returned to the detector the detector alarm may activate
until the impurities are “burned” off. This could take a number of hours, during
which time the alarm will be constantly “on”.