background image

PNEG 1433                               54” Galvanized Slant Wall Fan Installation Operation Manual                            - 15 - 

REPLACEMENT PARTS LIST FOR MODEL G54SCL16GA(NOMINAL VERSION)

 

COMPONENT DESCRIPTION 

QTY

 

PER 

017-1422-9 

Sheave 3.0" OD x 5/8" ID AK30 

10-0108 

Galvanized Cone Mounting Hardware 

12-0219 

          SW Conefan Conestrut Angle 

S-3611 

          Nut Flangwz 5/16-18 ZN YDP 

45 

S-6606 

          Bolt Flngs 5/16-18 x 3/4" ZN GR5 

45 

10-0103 

Cord / Terminal Bag - Galvanized Fans 

10-0102 

          Terminal Bag - Galvanized Fans 

S-7145 

          Cord, 96" 16/3 SJT w/Male 

10-0040 

Shutter Mount Hardware (12 pc) 

91-0042 

          Turnbutton Plastic Large 

12 

FH-1309 

          Lock Nut 1/2" #401 ARL. 

FH-1310 

          Connector 1/2" 

S-7279 

          Washer Flat 3/16" Alum (.50" OD) 

12 

S-7419 

          Screw SDS #10-16 x 1-1/4" HWH SS410 

12 

S-9248 

          Screw WS 1/4-10 x 1-1/2" FHP ZN 

12 

11-0345 

61” Grill Guard 

12-0200 Bottom 

Panel 

12-0201 Top 

Panel 

12-0202 Left 

Panel 

12-0203 Right 

Panel 

12-0210 Vertical 

Brace 

12-0211 Tensioner 

Bracket 

12-0212 Bearing 

Bracket 

12-0213 

Motor Mount bracket 

12-0214 

54" Venturi (55.25"ID) 

12-0215 Cone 

Panel 

12-0217 

Shaft 1" Diameter x 10" Long 

12-0218 

Prop (54.5" Diameter) 

15-0131 

Motor 1.5HP 1.5 SF / 1PH 1725RPM 50/60HZ 

16-0007 

Pulley AL104 x 1"  

16-0015 

Pulley AL94 x 1" (Used on G54SCL16GAHF) 

16-0076 

Bearing 1" Pillow Block 

16-0098 A-62 

V-Belt 

16-0097 

A-60 Belt (Used on G54SCL16GAHF) 

91-0057 

Rotary Tensioner w/ Splash Guard 

DC-1540 Decal, 

Danger/Warning 

DC-1571 

Decal, Grease Instructions 

DC-983 

Decal, AVS Logo  

DC-995 

Decal, !Warning Shear Point 

PNEG-1433 

54" Galv Slant Wall Fan Instruction Manual 

S-248 

Washer Flat 3/8 USS ZN YDP GR2 

S-3611 

Nut Flangwz 5/16-18 ZN YDP 

S-6606 

Bolt Flngs 5/16-18 x 3/4" ZN GR5 

S-7383 

Nut Nylock 3/8-16 ZN GR5 

S-7485 

Bolt Flng 3/8-16 x 1" GR8-JS500 

12 

S-9168 

Key SQ 1/4" x 1" 

S-9265 

Screw SMS 1/4-14 x 5/8" 

44 

S-9303 

Bolt Flng 3/8-16 x 1-1/2" GR8-JS500 

S-968 

Nut Flangwz 3/8-16 ZN GR5 

 

Содержание 54" SLANTWALL FAN

Страница 1: ...5 Replacement Parts List Congratulations You have just purchased one of the best Ventilation Fans in the industry designed to give years of high velocity airflow while saving hundreds of dollars in electrical usage Please take some time to read through this manual and familiarize yourself with the proper installation methods and operation of the fan FEATURES 9 One Year Warranty on Parts 9 Consiste...

Страница 2: ...no cost to end user 3 to 5 years end user pays 25 5 to 7 years end user pays 50 7 to 10 years end user pays 75 Warranty prorated from list price 0 to 3 years no cost to end user 3 to 5 years end user pays 50 Motors burner components and moving parts not included Portable Dryer screens included Tower Dryer screens not included Conditions and Limitations THERE ARE NO WARRANTIES THAT EXTEND BEYOND TH...

Страница 3: ...instructions is a misuse of the equipment and may lead to serious injury or death This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury DANGER indicates an imminentl...

Страница 4: ... wires cables or servicing equipment E L E C T R I C S H O C K H A Z A R D R E A D A L L L A B E L S R E A D A N D O B E Y P R O D U C T L A B E L S Read and obey all labels and instructions for products used in the fan K E E P H A N D S A W A Y F R O M M O V I N G P A R T S DO NOT put hand or arm in fan Rotating parts can crush and dismember DO NOT put any kind of tool inside fan to try and clear...

Страница 5: ... T I V E C L O T H I N G E Y E P R O T E C T I O N Wear close fitting clothing and safety equipment appropriate to the job G L O V E S Safety glasses should be worn at all times to protect eyes from debris S T E E L T O E B O O T S Wear gloves to protect your hands from sharp edges on plastic or steel parts R E S P I R A T O R A respirator may be needed to prevent breathing potentially toxic fumes...

Страница 6: ...ings and belt replacement will be required over the life of the fan Do not attempt any maintenance or repairs on the fan unless you are competent to do so Remember that the fan may in certain situations operate under automatic control and will start without warning Never attempt any work on the fan without first isolating it from the power supply and locking out the isolator so that only you can t...

Страница 7: ...A L S A N D L O C A T I O N S DC 1540 5 x 7 5 DANGER HIGH VOLTAGE WARNING STAY CLEAR OF ROTATING BLADE WARNING FLYING OBJECTS HAZARD LOCATED LOWER RIGHT CORNER INSIDE LOWER RIGHT CORNER OUTSIDE DC 995 2 0 X 4 5 WARNING SHEAR POINT LOCATED LOWER RIGHT CORNER INSIDE LOWER RIGHT CORNER OUTSIDE ...

Страница 8: ...aring portion of the bottom sill is rigid and properly supported Position the fan in front of the opening from the inside Using a minimum of two people lift fan housing into the opening Fasten flanges to framework with the wood mounting screws provided Check the fan for vertical position before screwing flanges down The fan housing should now be flush and level inside of the framing Important When...

Страница 9: ... the final two flanges meet Install bolts along this flange as the previous other three again leaving the top bolt and nut loose Install the cone panel brackets as shown in Figure 9 2 leaving the bolts and nuts finger tight Now using two people lift the cone panel assembly onto the venturi and align the holes of the brackets with the holes on the face of the fan Insert the 5 16 bolts into the hole...

Страница 10: ...with supplied 10 x 1 1 2 self drill screws spaced evenly refer to Figure 10 1 above with 3 per side with 3 16 spacer washer in between housing and the turnbutton If you do not wish to use the turnbuttons you may secure the shutter to the fan with 10 x sheet metal screws which are standard hardware items available locally Shutter Turnbutton Fan Housing ...

Страница 11: ...t motor rotation CCW the red wire should be located on the L2 connection as depicted If this is not the case switch the red and black wires Refer to the wiring diagram on the side of the motor for correct wiring for 115V and 230V supply Fans used to ventilate livestock buildings where continuous air movement is essential should be connected to individual electrical circuits with a minimum of two c...

Страница 12: ... refer back to Figure 11 1 and switch the black and red wires as noted after de energizing the fan Re check the operation and when satisfied the fan is operating properly follow the instructions below 9 Write down the date that your fan went into service and follow the maintenance schedule as listed below 9 Check the belt pulleys and the bearings after every two months of service The belt tensione...

Страница 13: ...hutter is jammed clogged Inlet outlet guards clogged by dirt debris Voltage supplied is not correct must be within or 10 of the nominal voltage Repair replace clean as necessary Repair replace clean as necessary Check line voltage at motor verify wiring Check with local utility supplier for possible line problems Excessive Vibration Fan blade has excessive dirt build up Motor driveshaft is bent Fa...

Страница 14: ...op Panel 1 6 12 0213 Motor Mount Bracket 1 7 017 1422 9 Sheave 3 0 Diameter 1 8 15 0131 Motor 1 5hp 1 5 S F 1ph 60Hz 1 9 12 0211 Tensioner Bracket 1 10 91 0057 Rotary Tensioner w Splash Guard 1 11 16 0007 Pulley AL104 1 12 16 0076 Bearing 1 Pillow Block 2 13 12 0212 Bearing Bracket 1 14 12 0210 Vertical Brace 2 15 12 0214 Venturi 1 16 12 0218 Prop 1 17 12 0219 Cone Bracket 4 18 12 0215 Cone Panel ...

Страница 15: ...l 1 12 0203 Right Panel 1 12 0210 Vertical Brace 2 12 0211 Tensioner Bracket 1 12 0212 Bearing Bracket 1 12 0213 Motor Mount bracket 1 12 0214 54 Venturi 55 25 ID 1 12 0215 Cone Panel 4 12 0217 Shaft 1 Diameter x 10 Long 1 12 0218 Prop 54 5 Diameter 1 15 0131 Motor 1 5HP 1 5 SF 1PH 1725RPM 50 60HZ 1 16 0007 Pulley AL104 x 1 1 16 0015 Pulley AL94 x 1 Used on G54SCL16GAHF 1 16 0076 Bearing 1 Pillow ...

Страница 16: ...PNEG 1433 54 Galvanized Slant Wall Fan Installation Operation Manual 16 PNEG 1433 ...

Отзывы: